DO NOT LET THE CHAIN BE RETRIEVED ENTIRELY IN ITS CASE BEFORE INSTALLING THE BRACKETS
Bottom-hung inward opening window: Overall dimensions and fixing holes
27
5.1 Installation sequence
-
Check that the width of the window, where the actuator is due to be fitted, is more than 400 mm. Otherwise, it is
NOT POSSIBLE to fit the actuator.
-
Check that the force required to open/close it (calculated according to the table under Point 4.2) is less than or
equal to that shown in the TECHNICAL DATA table.
-
Try manually the window opening, checking for and if necessary eliminating any sticking points that could cause
a malfunction.
-
Manually test the maximum opening of the window, checking that it is greater than the travel set by the actuator.
24
394
307
105
27
56
50