RUNTAL FOLIO GLASS
2 INSTALLING THE RADIATOR
2.1 WARNINGS
IMPORTANT: Before performing any mainte-
nance work, put the dial in the
the appliance to cool completely and dis-
connect it from the mains.
The flexible cable supplied with your appliance
is designed to be connected to the mains via
a junction box that must be placed behind the
appliance, with no need for a plug.
In a kitchen or bathroom, the junction box must
be positioned at least 25 cm from the floor.
The appliance must be installed as described
in this document and in accordance with the
applicable European and French standards,
including CEI 60364.7.701 and NF C15-100, as
well as the rules of good professional practice.
For other countries (apart from France), the
appliance must be installed in accordance with
standards in force and with rules of good
professional practice in the country of use.
28
position, allow
Volume 2
Volume 1
0.60 m
Volume 0
IMPORTANT The example shown only concerns
a bathtub. For other bathroom fixtures, please
consult your installer.
IMPORTANT The system must be fitted with
an omnipolar circuit-breaker with a minimum
contact opening of 3mm.
2.2 POSITIONING THE RADIATOR
To gain the full benefit of your appliance and
enjoy the highest standards of comfort, we
advise you to:
- install the radiator near places of high heat
loss (windows, doors, etc.) wherever possible.
- ensure that an area of at least 50 cm in front
of the appliance is clear of objects which
might hinder air circulation (furniture, arm-
chairs, etc.).
- ensure that the bottom of the control unit is
positioned at least 15 cm from the floor.
- not place the heating appliance underneath a
power outlet.
- use mounting screws suitable for your wall.
40016966
40016966
ENGLISH
29