Capteur d'énergie radio quadruple
Rel. threshold value, effective
power
Abs. threshold value, effective
power
Suppression length, effective
power
Averaging length
Information window
During channel selection in the Information window, the following values are displayed.
Display value
Voltage
Current
Effective power
Reactive power
Apparent power
Absolute active energy
Active energy
32582012
10864966
1 ... 50 %
Basic setting: 10 %
0 ... 2000 W
Basic setting: 1 W
0 ms ... 300 s
Basic setting: 0 ms
0.2 ... 300 s
Basic setting: 1 s
Explanations
Displays the current voltage value.
Displays the current current value.
Displays the current effective power.
Displays the current reactive power.
If negative values are displayed, this is capaci-
tive reactive power. Positive values show an
inductive reactive power.
Displays the current apparent power.
Displays the current absolute active energy.
If negative values are displayed, then effective
energy is fed in, e.g. via a photovoltaic sys-
tem.
Displays the cumulated active energy. Meter
reading can be set via settings window.
10.04.2017
The transmission of the
consumption data can be cou-
pled to the change in effective
power. The basis is always the
most recently transmitted ef-
fective output value. If the per-
centage change entered here
is exceeded, then all the mea-
sured values are resent.
A lower threshold value of the
effective power can be ente-
red here, to avoid frequent
transmission in the lower po-
wer range. Event-controlled
transmission is only active
above this threshold value.
Triggers for event-controlled
transmission are often switch-
on and switch-off operations.
In order to avoid incorrect
measured values due to
switch-on peaks, this parame-
ter can be used to enter a sup-
pression period. The measu-
red values are only transmit-
ted if the effective power is still
above or below the relative
threshold value after the set
time.
In the case of effective power,
it is not the current value
which is transmitted, as with
other measured values, but
the average value. It is pos-
sible to set the period for ave-
rage value formation here.