Problem
The
appliance
will not
turn on.
The
appliance
is not
working.
The vapor
has an
odor.
There is a
leak.
WSHUJ2158B_Digital Cool Mist Ultrasonic Tower Humidifier_2L_v2.indd 19
TROUBLESHOOTING
Possible Cause
•
The power cord
or adapter plug
is loose or not
connected.
•
There is not enough
water in the water
tank.
•
There is too much
water in the water
tank.
•
The water tank
is incorrectly
connected to the
base.
•
The appliance is
tilting.
•
The appliance is not
producing enough
vapor. There is a
build-up of dust or
scale.
•
The ceramic ball
filter is dirty and
water is not coming
into the water basin.
•
The appliance is not
producing enough
vapor as the water is
too cold.
•
The appliance may
be dirty.
•
The water tank or
vapor nozzle are
loose or incorrectly
assembled.
Solution
•
Check the power cord and
adapter plug. Make sure
they are firmly connected
to the mains socket and
base, respectively.
•
Refill the tank.
•
Remove some of the
water.
•
Firmly reattach the water
tank to the base.
•
Place the appliance on a
stable, even surface.
•
Touch the POWER button
to increase the vapor level.
•
Clean the vapor nozzle,
the inside of the base
and the water tank (see
CLEANING AND CARE).
•
Check the float ball and
oscillator in the base are
working and not damaged.
Clean if necessary (see
CLEANING AND CARE).
If damaged, take the
appliance to a qualified
service provider for repair.
•
Rinse the ceramic ball
filter under tap water.
•
Put some warm water in
the water tank.
•
Clean the oscillator, the
inside of the base and the
water tank (see CLEANING
AND CARE).
•
Replace the old water in
the tank with clean water.
•
Check and reinstall the
water tank and vapor
nozzle.
EN
19
7/7/2020 3:07:58 PM