Problem
The
appliance
will not
turn on.
The
appliance
is not
working.
The vapor
has an
odor.
There is a
leak.
WSHUJ2158B_Digital Cool Mist Ultrasonic Tower Humidifier_2L_v2.indd 19

TROUBLESHOOTING

Possible Cause
The power cord
or adapter plug
is loose or not
connected.
There is not enough
water in the water
tank.
There is too much
water in the water
tank.
The water tank
is incorrectly
connected to the
base.
The appliance is
tilting.
The appliance is not
producing enough
vapor. There is a
build-up of dust or
scale.
The ceramic ball
filter is dirty and
water is not coming
into the water basin.
The appliance is not
producing enough
vapor as the water is
too cold.
The appliance may
be dirty.
The water tank or
vapor nozzle are
loose or incorrectly
assembled.
Solution
Check the power cord and
adapter plug. Make sure
they are firmly connected
to the mains socket and
base, respectively.
Refill the tank.
Remove some of the
water.
Firmly reattach the water
tank to the base.
Place the appliance on a
stable, even surface.
Touch the POWER button
to increase the vapor level.
Clean the vapor nozzle,
the inside of the base
and the water tank (see
CLEANING AND CARE).
Check the float ball and
oscillator in the base are
working and not damaged.
Clean if necessary (see
CLEANING AND CARE).
If damaged, take the
appliance to a qualified
service provider for repair.
Rinse the ceramic ball
filter under tap water.
Put some warm water in
the water tank.
Clean the oscillator, the
inside of the base and the
water tank (see CLEANING
AND CARE).
Replace the old water in
the tank with clean water.
Check and reinstall the
water tank and vapor
nozzle.
EN