Würth 0715 58 550 Traduction Des Instructions De Service D'origine page 30

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 51
3.9 Measuring Temperature
To avoid electrical shock and damage to the meter when
measuring a temperature, make sure that the surface in contact
with the K thermocouple has no voltage.
1. Turn the rotary switch to
.
2. Toggle the yellow key to choose between °C and °F.
3. Plug the K thermocouple into the + and COM terminal, insuring the thermocouple
plug marked with a + symbol is connected to the + terminal.
4. Read the temperature in degree on the display. While doing the measurement
make sure to keep the meter within its working temperature.
After inserting the plug into the meter, allow 1 minute for thermal stabilization.
If no thermocouple the meter will display its internal temperature if above 0°C.
If temperature measured is above 1300°C the LCD will display OL.
30

Publicité

Table des Matières
loading

Table des Matières