Using the CO & Smoke Detector
Installing the battery
Connect a new 9-volt battery to the connector. Do not use a rechargeable battery. The
battery will fit only one way. Be sure the battery connector is securely attached.
Place battery into battery pocket.
Alarm
Every alarm type has its own individual character.
CO alarms will sound as four short alarm beeps and continuous beeps will sound when
smoke is detected. In case both are detected simultaneously the smoke pattern alarm will
sound.
One "chirp" every 30 seconds will be an indication that the battery is low or the unit is
malfunctioning. In case of a low battery level, replace the battery as soon as possible.
As you install the battery, the unit will sound "chirp" to indicate the battery is installed
properly.
The red LED will flash in conjunction with the alarm beep. I.e., the red LED will flash during a
CO alarm, a fire alarm and a low battery mode chirp.
Testing the detector
Press the test button for several seconds to test the detector's electronics. The alarm will
sound.
NOTE, Do this weekly to ensure correct functioning.
Technical Specifications
Power Source :
Sensitivity Setting :
CO :
SMOKE :
Power consumption :
Standby :
Alarm :
Operating Temperature :
Ambient Humidity :
Horn Level :
10-9-2008
9V battery (Alkaline or Carbon Zink)
100 +/-50ppm CO concentration
1%~5%/FT OBS
< 100uA
< 75mA
5° ~ 40°C
20~90% RH
85 Decibels