Control Elements; Technical Data; Intended Use; Safety Information - Collomix AQiX Manuel D'instructions

Doseur d'eau
Masquer les pouces Voir aussi pour AQiX:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
EN

Control elements

1
Display
2
Key field
3
Battery compartment
4
Connection thread 3/4" for hose coupling
5
Sieve insert
6
Retaining bracket
7
Water outlet
8
Storage tank for quantity 1
9
Storage tank for quantity 2
10
Manual dosing / zeroing
11
Setting the quantity + /-
12
Start button / pause
You have purchased the new AQiX water dosing system.
Please note that this is a meter and it should be handled
with care. These instructions contain important and useful
information for how you should use the device. Please read
the instructions carefully.
The numbers in the text relate to the overview on page 2.

Technical data

Measurable water quantity:
Min. / max. operating pressure
Device operating temperature
Flow medium
Flow speed min. - max.
Max. water temperature
Accuracy
IP protection class
Batteries
Weight

Intended use

The Collomix AQiX water dosing system is intended for use
by professionals or trained personnel on construction sites
for the precise addition of water for mixing building chem-
ical products (such as mortar, plaster, screed, concrete, fill-
ers and the like).
It is used to precisely meter amounts of water.
1 - 99 litres
2 - 6 bar
+ 5°C - + 50°C
Clear freshwater
10 ltr/min - 25 ltr/min
+ 40°C
1-3 litre ± 60 ml
> 3 l ± 2%
IP 64
2 x AA/IEC LR6 1.5 V
688 grammes
The water dosing system may only be used with clear
freshwater at a water temperature of up to 40°C.
The Collomix AQiX water dosing system is not designed for
industrial use.
It is not permitted to use the meter with salt water, chem-
icals, foodstuffs, spirits, highly flammable and explosive
substances as well as compressed air. Using these sub-
stances may destroy the device.
The operating temperature must be between +5°C and
+50°C. Do not expose the device to direct sunlight for
longer periods of time.
The water pressure in the line must be between at least 2
and a maximum of 6 bar so that the device works flawlessly.
Please note that this device is not a calibrated meter.
Fluctuations can be caused by factors such as varying
water pressure, etc.
Safety information
l
WARNING: Read all safety information and
instructions. Failure to observe the safety information and
instructions may result in injuries or damage to the device.
Store these instructions for the future.
The device may only be used by persons familiar with
the operating instructions and the applicable regulations
regarding occupational safety and accident prevention.
For safety reasons, children and adolescents under the age
of 16 as well as persons who have not familiarised them-
selves with this operating manual may not use this product.
Persons with restricted physical or mental abilities may
only use the product if supervised or instructed by a com-
petent person.
Children must be supervised in order to ensure that they
do not play with the product.
Never use the device if you are tired or ill or under the in-
fluence of alcohol, drugs or medication.
ATTENTION!
Do not use in freezing conditions. Freezing water will de-
stroy the device.
Only connect the supply hose to the provided connection,
not to the water outlet!
Only intended to be used with the suitable hose couplings
with ¾" thread.
Avoid tensile loads: Do not pull at the connected hose.