VONROC HA501AC Traduction De La Notice Originale page 7

Masquer les pouces Voir aussi pour HA501AC:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

• Smelting synthetics, among which matters and
foils with PVC layer;
• Applying heat shrinking tubes;
• Shrinkwrappers;
• Thawing tubes and engines;
• Repairing finishing layers: enamel of bath and
household appliances; applying epoxypowder
coverlayers;
• Repairing of ski's, surf-boards and other sports
goods;
• Unscrewing too fast fixed screws and connections.
Operation (Fig. A)
You can work manually with this hot air gun or you
can put it in a vertical position.
• Check if the mains switch is on position "0"
before you connect the apparatus;
• Keep the main lead always away from the hot
air stream and the mouth piece;
• Put the mains switch in position 'I or II' to let
your hot air gun operate:
"I" = 400 degrees, air flow 250 l/min.
"0" = Off
"II" = 600 degrees, air flow 500 l/min.
Switching off:
Slide the switch to 0.
Tip: If you want to get the best result, test all appli-
ances on a little part of the workpiece.
Flat rear side (Fig. C)
Inbetween usage, the machine can easily be placed
on its flat rear side (7). This prevents any hot area
from the machine getting into contact with other
surfaces
The flat rear side (7) also allows the machine to be
used in upright stationary mode.
After usage, always place the machine on its flat
rear side (7). This allows the machine to cool down
safely.
Use of accessoires (Fig. B)
Fishtail nozzle (4)
Distributes air equally over flat wide area.
Reduction nozzle (5)
Distributes air equally over small areas
WWW.VONROC.COM
Glass protection nozzle (6)
Deflects air away from glass for example when
stripping paint in window frames or softening putty.
4. MAINTENANCE
Always disconnect the apparatus before
carrying out inspection or cleaning. Never
use water or other liquids to clean the
electrical parts of the hot air gun.
• Never use easy inflammable liquids for cleaning
the hot air gun, especially for the mouthpiece.
• Regular maintenance of your hot air gun
prevents unnecessary problems. Keep the ven-
tilation slots of the hot air gun clean to prevent
overheating.
Troubleshooting
In case the hot air gun does not work well, we give
you subjoined some possible causes and their
solutions.
• The engine gets overheated.
• The ventilation slots of the hot air gun are dirty.
Clean the ventilation slots.
• The hot air gun does not start when it is
switched on.
• Interruption in the electrical circuit.
Check the mains lead and the mains plug.
• The switch is defective.
Pull the mains lead out of the wall socket, be-
cause there is a chance of fire risk! Have the hot
air gun repaired at your local dealer.
• The engine does not work, but it does heat.
• Interruption in the electrical circuit.
Pull the mains lead out of the wall socket,
because there is a chance of fire risk! Have the
hot air gun repaired at your local dealer.
ENVIRONMENT
Faulty and/or discarded electrical or
electronic apparatus have to be collected at
the appropriate recycling locations.
EN
7

Publicité

Table des Matières
loading

Table des Matières