START UP AND OPERATING RECOMMENDATIONS
To ensure correction operation of the venturi injector
dechlorination kit, the opening of the Ø50 ¼ turn
valve must be adjusted:
1.
Open the Ø50 ¼ turn valve fully.
2.
Place the end of the Ø8x12 tube into a small
recipient filled with water (such as a glass of
water).
3.
Set the 6-way multi-port valve to back wash.
4.
Start the filtration pump.
5.
Close the Ø50 ¼ turn valve slowly and gradually
until injection starts. When injection starts, air
bubbles will be seen moving through the flexible
Ø8x12 tube.
6.
Monitor the flow for a few minutes to make sure
that injection proceeds properly. Over a 2 minute
7.

LIMITATIONS OF USE

ƒ
Install the venturi injector head down to ensure
smooth injection.
ƒ
Install the container of Neutral at the same height,
or higher than, the venturi injector.
ƒ
Do not fully close the ¼ turn Ø50 valve during a
back wash. This could damage the pump.
ƒ
Neutral should be protected from light, heat and
cold.
Safety advice and recommendations
Recommendations taken from the Neutral material
safety data sheet:
ƒ
Wash hands carefully after use.
ƒ
Store out of the reach of children.
ƒ
Toxic if ingested.
ƒ
In case of ingestion, seek medical advice
immediately and show the packaging or label to
the health professional.
period, between 2 and 10 cl of water will be
injected (this will depend on the pump used).
7.
The ¼ turn Ø50 valve setting will not need any
further adjustment. You may remove the handle
to prevent it from being accidentally altered.
Caution: The more closed the ¼ turn valve, the
lower the back wash flow rate.
an effective back wash, close the valve as little as
possible (just enough to achieve injection).
ƒ
Store apart from foods, drinks, including animal
feed.
ƒ
Avoid contact with the eyes.
ƒ
Will release a toxic gas on contact with an acid.
ƒ
Do not mix with acids.
ƒ
Do not mix with bases.
Troubleshooting
If Neutral is not being injected:
ƒ
Check that the venturi injector is correctly
oriented.
ƒ
Make sure that the container of Neutral is not
lower than the venturi injector.
ƒ
Check that the ¼ turn valve is closed just enough
to allow injection of Neutral.
ƒ
Check that the vent in the cap of the container of
Neutral is not blocked.
2014/02 - Indice de révision : A - Code : 29781
In order to ensure
7/12