Operating Instructions
Read Head CEM-A-LE05H-S2
Setting adhesive force
To change the preset adhesive force, you will need
a programming adapter (order No. 110013).
Proceed as follows:
Remove cable from plug connector X1
f
Connect programming adapter to plug connector
f
X1
Connect the connection cable to the programming
f
adapter and switch on the operating voltage (UB).
The CEM is in programming mode and succes‑
sively clocks through the adjustment ranges
(see table). This process repeats itself until the
operating voltage (UB) is switched off.
on
LED
off
70 N
110 N
Sequence of flashes
(respectively shown three times)
Flashing 1x
Flashing 2x
Flashing 3x
Wait until the sequence of flashes indicates the
f
correct adhesive force and remove the program‑
ming adapter before the device changes to the
next sequence of flashes.
The corresponding adhesive force is saved and
is available the next time the device is put into
operation.
Typical actuating range
Observe safe switch-off
distance s
= 20 mm on
ar
internal component failure.
Safety outputs are safely
switched off.
OFF
-4
-3
-2
Figure 2: Typical actuating range
Service and inspection
WARNING
Loss of the safety function because of damage
to the device.
In case of damage, the related safety component
f
must be replaced. The replacement of individual
parts in a safety component is not permitted.
Regular inspection of the following is necessary to
ensure trouble‑free long‑term operation:
Check the switching function
f
Check the secure mounting of the devices and
f
the connections
Check for soiling
f
Check for sealing of the plug connector on the
f
safety switch
Check for loose cable connections on the plug
f
150 N
connector
Check the release distance
f
Adhesive force
No servicing is required. Repairs to the device are
only allowed to be made by the manufacturer.
approx. 70 N
NOTICE
approx. 110 N
The year of manufacture can be seen in the lower
approx. 150 N
right corner of the type label.
Exclusion of liability and warranty
In case of failure to comply with the conditions for
correct use stated above, or if the safety regula‑
tions are not followed, or if any servicing is not
performed as required, liability will be excluded and
the warranty void.
With evaluation unit CES‑AZ‑...B
m
Actuator
s
Read head
4
Release
3
distance
Hysteresis
2
Operating
distance
1
ON
ON
0
1
-1
Center offset m [mm]
Output state
Hysteresis
ON
OFF
S
Distance s
a0
OFF
2
3
4
5
Technical data
Read head
Parameter
Value
Material
‑ Housing
Aluminum
‑ Read head CES
Plastic (PPS)
‑ Solenoid
Steel, nickel‑plated
Weight
0.3 kg
Mechanical life
1 x 10
(closing cycles)
6
Installation position
Any
Degree of protection
IP67
Ambient temperature
‑25 ... +50 °C
Actuating range for center offset
m=0
‑ Assured release distance S
20 mm
ar
‑ Assured operating distance S
2 mm
ao
‑ Switching hysteresis
0.7 mm
Connection to evaluation unit
Plug connector M8 (male
(plug connector X3)
socket, 3‑pin), suitable
for snap‑action and screw
terminals
Max. cable length
25 m
Solenoid
Adhesive force, adjustable
70 N, 110 N (factory setting),
150 N
Locking force
650 N (not monitored)
Max. permissible center offset
between solenoid and anchor
± 2.5 mm
plate
Operating voltage U
DC 24 V +10%, ‑15%,
B
(plug connector X1)
reverse polarity protected
Current consumption at
connection X1.2 (U
) at
B
‑ U
= 24 V
100 mA
CM
‑ U
= 0 V
25 mA
CM
Duty cycle
100%
Power consumption
Approx. 2.8 W
Operating voltage connection U
Plug connector M8 (male
B
(plug connector X1)
socket, 4‑pin)
LED, yellow, integrated into the
plug (see circuit diagram)
1) At an impact energy of max. 1 Joule
Actuator CEM-A-BE05...
Parameter
Value
Material
‑ Housing
Aluminum
‑ Read head CES
Plastic (PPS)
‑ Anchor plate
Steel, nickel‑plated
Weight
Approx. 0.18 kg
Installation position
Active face opposite CES
read head
Degree of protection acc. to
IP67
IEC 60529
Ambient temperature
‑25 ... +50 °C
Adjustment angle (around point X,
± 4°
see dimension drawing)
1)