CANALIZZAZIONE ALLA POTENZA NOMINALE
Canalisation at nominal heat output
120
110
100
90
80
70
60
50
0
1
2
Lunghezza tubo di canalizzazione [m]
2.7 Electrical connection
Connect one end of the power cable the wall socket.
The voltage supplied by the system must match that specified on the stove dataplate and in the technical data
section of this manual.
Plug the device power cord must be connected only AFTER the end of the installation and assembly of the device
and must remain accessible.
During stove idle periods it is advisable to remove the power cable. ( Wiring diagram – fig. 3)
- Make sure the electrical system complies with the regulations, and has an earth and differential switch in conformity
with the current Standards.
- The power cable must never touch the exhaust pipe and the hot parts of the stove.
2.8 Emergency
Suitable fire-prevention devices should be arranged for any eventuality.
In case of a fire, proceed as follows:
- Immediately disconnect the plug.
- Extinguish the fire using suitable fire-extinguishers.
- Call the fire department immediately.
- Do not use jets of waters to extinguish the fire.
3 STOVE SAFETY
3.1 Safety distance from flammable materials
To prevent the risk of fire, stove positioning must respect a minimum distance from flammable materials, according
to that given in the technical table of the manual and on the dataplate.
Pay attention to the type of floor: for delicate and flammable materials it is advisable to use plates in steel or
toughened glass as a support base (see section 2 - Transport and Installation). In case of particularly fragile objects
such as furniture, curtains or sofas, increase the stove distance considerably.
3.2 Fume exhaust safety
In normal operation the combustion chamber is in a negative pressure, guaranteeing seal against possible smoke
leaks in the room. If a certain vacuum level is not reached or the fume exhaust outlet is blocked, the vacuum switch
detects the lack of a negative pressure inside the combustion chamber or the air flow meter detects a lack of air flow
and, through the electronic controller, switches off the auger rotation motor, signalling the anomaly with a message
on the control panel 'AL 8 NO NEG PRESS' or 'AL 9 INSUF DRAUGHT'.
3.3 Combustion chamber overpressure safety
Any and/or sudden overpressures in the combustion fumes inside the chamber and fume exhaust ducts are
discharged by opening of the safety valves located on the heat exchanger. During normal operation these valves
are kept closed by their weight and the negative pressure in the combustion chamber, guaranteeing a seal against
any smoke escaping.
Periodically check closing, the integrity of the device and its operation.
Isolated pipe
Not isolated pipe
3
4
5
Canalisation pipe length (m)
140
120
100
80
60
40
20
0
6
7
8
0
40
Air capacity [m3/h]
Output pressure [Pa]
1
2
3
4
5
Canalisation pipe length (m)
Lunghezza tubo di canalizzazione [m ]
6
7
8
AFRODITE