Technical data:. SZ 4138.140, .180, .300
Protection type:
Protection class:
Light bulb:
Base:
Switching function:
Rated voltage:
Rated current:
Rated frequency:
Ambient temperature:
Socket:
Lamp start:
Service life:
Connector type:
Certifications:
Testing standard:
Electromagnetic emission:
Emission immunity:
Dimensions:
Length:
455 mm
685 mm
Width:
50 mm
Height:
120 mm
120mm
Weight:
2.5 kg
Notes on operating the lamps
Lamps SZ 4138.140, .180 and .300 are only suitable for use in the interior of enclosures.
The connectors are to be checked before operating the lamps to ensure that they are correctly inserted and properly
clamped down.
The connecting wires for the lamps are to be fixed along their entire length using suitable fasteners, e.g. cable ties.
The lamps are to be disconnected from their power supply when measuring the insulation resistance of enclosures or
equipment.
Caution:
Lights connected in series and with magnetic ballast create overvoltage peaks when they are switched on and off,
which may impair or damage the function of voltage-sensitive equipment.
Measures to reduce these overvoltage peaks (e.g. RC modules) must be taken by the customer.
When connecting equipment using the lamp sockets, it must be ensured that the cables are laid so that there is no
danger of stumbling over the cables.
The power cord may not be clamped between the enclosure and the door when the enclosure door is accidentally
slammed shut.
Power connection
Check the supply voltage before operating !
The lamp(s) can be connected individually and are suitable for use in a lead-through wiring schema.
The connection accessories are to be used to connect the lamp(s) (see item SZ 4315xxx). Item SZ 2507 can be used
as a fuse and as a connecting component.
Max. number of lamps in a lead-through wiring schema:
20 pieces
Observe the maximum outlet power rating !
Imax. 10A or 16A
Fuses:
Connecting component with 10A line circuit breaker:
Alternative:
IP 20
1
L14W/25-T8, L18W/25-T8, L30W/25-T8
G13
On/Off
230VAC
0.31A
50 Hz
25°C
Single pole, 16A
Cold start >=0.4 sec. at +20°C
10,000 h
Input connector type GST 18 (female)
Output connector type GST 18 (male)
CE, ENEC, GS
EN 60598-1
EN 55 015
EN 61000-6-2
990 mm
50mm
50 mm
120 mm
2.5 kg
3.25 kg
SZ 2507
10A or 16A line circuit breaker