the UNI 10683-2005 Regulation –Italy requires that the bends or variations of direction must in no case be
greater than 2 including the emission into the flue.
Wanting to use the flue of a chimney or open furnace, it will be necessary to close the hood hermetically below the
inlet point of the smoke channel pos. A Picture 9.
If the flue is too large (e.g. cm 30x40 or 40x50) it is necessary to duct it with a stainless steel tube of at least 200 mm
of diameter, pos. B taking care to close the space between the tube itself and the flue immediately below the chimney
cap pos. C.
7196601 – EN
For further information please contact your Dealer.
C - Plugging
B
A – Hermetic closure
Inspection
hatch
Picture 9