Installation; Recommended Tools And Accessories For Installation; Install Ductwork (Ducted Installations Only) - Venmar CHEF VCNDD1 Série Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

For ADA compliance installation guidelines, please type the model number into our website.
Recommended Tools and Accessories
for Installation
Measuring tape
Phillips screwdriver no. 2
Flat blade screwdriver (to open knockout holes)
Drill, 1/8" drill bit and 1½" hole saw (to mark holes for ducting and cut electrical access hole)
7/64" drill bit (to drill holes for EZ1 brackets mounting screws)
7" round duct plate, not included (for 7'' round vertical ducting installation, part no.: SR680508)
Wood shims (2) and wood screws (4) (required for standard installation to framed cabinet)
Saw (to cut holes for ducted application)
Sheet metal shears (ducted installation only, for duct adjustment)
Pliers (ducted installation only, for duct adjustment)
Metal foil duct tape (for ducted applications)
Scissors (to cut metal foil duct tape)
Pencil
Wire stripper
Strain relief, 1/2" diameter (to secure house wiring cable to the hood)
BP87Q Damper (needed if 7-in. round duct is used)

Install Ductwork (Ducted Installations Only)

S
C
ABINET
18"
MIN
ABOVE COOKING SURFACE
NOTE: Distances over 24" are at the installer and user discretion.
1 ] Determine whether hood will discharge vertically (3¼" x 10" or 7" round),
or horizontally (3¼" x 10" only).
2 ] Decide where the ductwork will run between the hood and the outdoors.
3 ] Choose a straight, short duct run to allow the hood to perform most efficiently. Long duct
runs, elbows and transitions will reduce the performance of the hood. Use as few of them as
possible. When possible, use at least 2-foot straight runs before any turns. Larger ductwork
may be required for best performance with longer duct runs.
NOTE: To use 6" round ducting, install a 3¼" x 10" to 6" round transition (not included). The
performances may be affected.
4 ] Install wall cap or roof cap (sold separately); ensure there is no leak in house insulation.
Connect metal ductwork to cap and work back towards the hood location. Use 2" metal foil
duct tape to seal the joints between ductwork sections.
R
OOF CAP
OFFIT
H
OOD
- 24"
MAX
3¼"
10"
X
OR
7"
ROUND DUCT
(F
OR VERTICAL
)
DISCHARGE
H
OUSE WIRING
(T
)
OP OR BACK OF HOOD
W
ALL CAP
3¼"
10"
X
DUCT
(F
OR HORIZONTAL DISCHARGE
)
7