Status - EcoNet RETST700SYS Guide D'utilisation

Masquer les pouces Voir aussi pour RETST700SYS:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Status

Menu
80
80
Resume Schedule
71
75
Settings
Schedule
Status
Home
Away
Water Heating
Cooling to
65
70
BACK
Status
80
80
Resume Schedule
75
71
Furnace
AC/HP
Air Handler
Inside Temp : 77º
Outside Temp : 80º
Home
Away
Inside Rel. Humidity : 39%
Thermostat Mode : Off
Equipment Operating Status : Off
Cooling to
70
65
BACK
Furnace Status
80
80
Current ->
Capacity :
0%
CFM :
0
Resume Schedule
71
75
Temperatures ->
Outside :
80º
Supply :
0 º
Discrete Inputs ->
G :
off
Aux 1 :
off
Static Presure :
0.00 in.
Lo Heat
Hi Heat
Blower
Home
Away
Two Week Cycles :
0
0
0
Two Week Hours :
0
0
0
Lifetime Cycles :
0
0
0
Cooling to
Lifetime Hours :
0
0
0
70
65
BACK
AC/HP Status
80
80
Unit Type :
AC
var-speed
2 tons
Resume Schedule
75
71
Outside Temp:
68°
Hold-off Timer:
0
Utility Input : Disabled
Lo cool
Hi cool
Two Week Cycles :
1
1
Home
Away
Two Week Hours :
0
0
Lifetime Cycles :
2
6
Cooling to
Lifetime Hours :
0
2
70
65
BACK
AC/HP Status
80
80
Inverter Current Speed ............ 0 RPM
Resume Schedule
75
71
Crankcase Heater Temp ......... 68.7°
Superheat ........................... 60.0°
Home
Away
Suction Line Temp ............... 9.1°
Suction Pressure .................. 4.2 PSIG
Cooling to
65
70
BACK
Air Handler Status
80
80
Current ->
Elec. Heat :
off
CFM :
0
Resume Schedule
75
71
Supply :
--
Temperatures ->
Discrete Inputs ->
G :
off
Aux 1 :
off
Static Presure :
0.00 in.
Lo Heat
Hi Heat
Blower
Home
Away
Two Week Cycles :
0
0
20
Two Week Hours :
0
0
0
Lifetime Cycles :
3
3
112
Cooling to
Lifetime Hours :
0
6
115
70
65
BACK
Air Handler Status
80
80
EXV Current Position ............ 96.0%
Resume Schedule
71
75
EXV Current Superheat ......... 30.0°
Suction Line Temp ............... 69.1°
Saturated Suction Temp ......... -40.0 °
Suction Pressure .................. 3.6 PSIG
Home
Away
Cooling to
65
70
BACK
> Return to Table of Contents
Tapping Menu > Status will display the connected communicating
equipment, thermostat mode and the equipment operating status.
Service
44%
44%
Selecting Furnace, Air Handler or AC/HP on the Status screen will display
each piece of equipment's current operating status and historical cycles and
run times.
44%
44%
MORE
Furnace Status – Displays detailed furnace operation information including
two week and lifetime cycles, as well as run time hours.
RPM :
0
Return :
0 º
Aux 2 :
off
Powered
44%
44%
0
n/a
0
0 days
AC/HP Status – Displays detailed AC/HP operation information including two
week and lifetime cycles, as well as run time hours.
44%
44%
MORE
44%
44%
Air Handler Status – Displays detailed air handler operation information
including two week and lifetime cycles, as well as run time hours.
RPM :
0
Return :
--
Aux 2 :
off
Powered
44%
44%
4
n/a
20
85 days
MORE
44%
44%
EcoNet
Smart Thermostat User Guide
®
18