INTRODUCTION
The Wavetek digital multimeter HD160B is a Heavy Duty 4-digit, autoranging, AC-
coupled true RMS measuring instrument that measures voltage, current,
resistance, continuity and diode junctions. It also has a Safety Tester™ to indicate
that a voltage is present, even if the meter's battery is dead. Menu selection allows
Range Lock, Probe Hold, Relative Measurement, Auto Min Max Measurement and
backlight ON/OFF. The instrument is completely sealed.

WARNINGS AND PRECAUTIONS

This instrument is EN61010-1:1993 certified for Installation Category III,
1500VDC/1000VAC. It is recommended for use in distribution level and fixed
installations, as well as lesser installations, and not for primary supply lines,
overhead lines and cable systems.
All inputs are protected against continuous
overload conditions up to the limits of each function's stated input protection (see
specifications). Never exceed these limits nor the ratings marked on the
instrument itself.
For voltage measurements, the circuit under test must be
protected by a 20A fuse or circuit breaker.
Exercise extreme caution when:
measuring voltage >20V, current >10mA, AC power line with inductive loads, AC
power line during electrical storms. High voltages can be lethal and high voltage
transients may occur at any time.
Operator injury or damage to the multimeter
may occur during current measurements if the fuse blows in a circuit with open
circuit voltage >600V (500V in mA input).
Always inspect your DMM, test
leads and accessories for signs of damage or abnormality before every use. If an
abnormal condition exists (broken or damaged test leads, cracked case, display
not reading, etc.), do not use.
When testing for voltage or current, make sure
these ranges function correctly. Take a reading of a known voltage or current first.
n Never ground yourself when taking measurements. Do not touch exposed metal
pipes, outlets, fixtures, etc., which might be at ground potential. Keep your body
isolated from ground and never touch exposed wiring, connections, test probe
tips, or any live circuit conductors. Do not use the Flex-Strap to attach the meter
to your body.
Always measure current in series with the load – NEVER connect
the multimeter ACROSS a voltage source. Check fuse first.
Never replace a fuse
with one of a different rating.
Do not operate instrument in an explosive
atmosphere (flammable gases, fumes, vapor, dust.)
Do not use this or any
piece of test equipment without proper training
CRT SERVICE SAFETY
REMINDER : A potential danger exists when measuring voltages in the horizontal
output and damper stages of CRT equipment. (High voltage transients greater than
- 2 -