POMPE MGD+
3.1 ELECTRIC CONNECTIONS
▪ Make sure the electricity supply voltage and frequency correspond to the values specified on the pump data plate.
▪ The pump's electrical system must be fitted with a differential guard with a value of no more than 30mA.
▪ When wiring the pump motor terminal board, make sure the electrical terminals are tightened properly and make
the earthing connection correctly.
▪ Check that the adjustment of the thermal relay in the electrical cabinet matches the pump motor intensity in order
to ensure the effective protection of the latter (see the pump data plate).
Single-phase pump terminal board
▪ In the event of a three-phase motor: make sure the motor is revolving clockwise (looking at the fan - see the arrow
on the top of the fan).
▪ Neither the motor nor any of the live parts must come into contact with water.
▪ Make sure the electrical wires are sheathed.
▪ Check the correct positioning of the cable at the terminal board input in order to avoid any water seeping in through
the wire passage.
▪ This pump MGD+ has a drain plug in stainless steel for the earthing. For the connection, you have an electric cord in
the box to link the plug to the motor housing. If you want to change the connection, you can link the drain plug in
stainless to another ground.
3.2 HYDRAULIC SYSTEM
▪ Connect the pump to the swimming pool's hydraulic circuit using the couplings provided.
▪ To connect the pipes to the pump, the joints are supplied with O-rings which must under all circumstances be
used.
▪ The pipes must be connected to the couplings and glued in place.
▪ The delivery pipe must be fitted at a right angle and perfectly centered with respect to the outlets to be connected,
so as to avoid the pump and pipe from being subjected to external stresses which could cause them to break, irrespective
of the assembly operations. We recommend a vertical pipe length of approx. 60cm to facilitate the priming of the pump.
▪ A slight tilt of the suction pipes (2%) will prevent any air pockets from forming.
15 Rue des Marais 44310 ST Philbert de Gd Lieu – Tel. 02 40 59 95 35 – www.acis-france.com
MGD+ PUMP
Three-phase pump terminal board
8