Metabo HPT NT 1865DMA Manuel D'instructions Et De Sécurité page 31

Masquer les pouces Voir aussi pour NT 1865DMA:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PROBLEM
Nailer doesn't operate
(Power switch ON).
Nailer operates, but no nail is driven.
Weak drive.
Slow to cycle.
Drives too deep.
Skipping nails.
Intermittent feed.
Nails jam.
Driven nail is bent.
CHECK METHOD
Nailer not enough pressed against
workpiece.
Trigger not enough pulled.
More than 2 seconds pass from push
lever ON to trigger ON (or trigger ON
to push lever ON).
Preventive mechanism activated.
(No nails, or too few fasteners
remaining) (NT1865DMA /
NT1865DM only)
Lock lever(Trigger lock function) is
"ON" position.
Machine is too cold (below 23°F
(-5°C)) or too hot. (LED light blinks at
regular intervals, and power switch
goes off after 10 seconds.) (Refer to
page 20)
Damaged internal electronics.
Magazine is dirty.
Check for a jam.
Driver blade worn or damaged?
Ribbon spring weakened or
damaged?
Nail feeder damaged?
Check for proper nails.
Check position of nailing depth
adjustment adjuster.
Driver blade worn?
Compressed air pressure has
become low.
Damaged internal electronics.
Check position of nailing depth
adjustment adjuster.
Check for proper nails.
Nail feeder damaged?
Ribbon spring weakened or
damaged?
Driver blade worn or damaged?
Check for proper nails.
Driver blade worn or damaged?
CORRECTION
Hold nailer fi rmly and press to the
workpiece completely.
Pull the trigger fi rmly.
Make sure that less than 2 seconds
pass between push lever ON and
trigger ON (or between trigger ON
and push lever ON).
Reload the nails into magazine.
Set Lock lever to "OFF" position.
(Refer to page 20 – 21)
Allow the nailer to cool or warm-up
throughly in adequate condition.
Contact metabo HPT for replacement.
Blow and wipe clean the magazine.
Clear a jam (refer to page 28).
Contact metabo HPT for replacement.
Replace ribbon spring.
Replace nail feeder.
Use only recommended nails.
Readjust according to page 27.
Contact metabo HPT for replacement.
Contact metabo HPT for replacement.
Contact metabo HPT for replacement.
Readjust according to page 27.
Use only recommended nails.
Replace nail feeder.
Replace ribbon spring.
Contact metabo HPT for replacement.
Use only recommended nails.
Contact metabo HPT for replacement.
English
31

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Nt 1865dmNt 1850de

Table des Matières