I
nstallatIon manual
General information
If the insert is to be mounted in a newly built, non-approved open fireplace, all legal requirements and
local building regulations must be observed . It would always be advantageous to consult your chimney
sweep before mounting the insert .
Always follow the instructions of the manual carefully and make sure that the installation is carried out
by a qualified professional . HWAM packaging material should always be handled in accordance with the
local rules for waste handling .
Room requirements
There must be a constant supply of fresh air to the room in which the insert is to be installed . A window
that opens or an adjustable air vent should suffice .
Please be aware that not all glass parts are heat-resistant . For this reason, a glass wall should sometimes
be treated as a flammable wall, in which case we ask you to contact your local chimney sweep or glass
producer to hear at what distance the insert should be kept from glass .
Technical data
Model
HWAM I30/55s
The stove is mainly made of sheet iron .
Test results from nominal test EN 13229:
Nominal heating effect
Smoke temperature
Exhaust gas flow
Efficiency
Distance to inflammable materials
Please refer to local building regulations to determine the size of the fireproof area in front of the fireplace .
The insert must be positioned at least 30 cm above the floor if the floor is made of flammable material .
If there is inflammable material around the outer casing, non-inflammable insulation (Fire Batts) is required
between the casing and the inflammable material . The insulation must be 80 mm thick on both sides of
the casing, 120 mm behind the casing and 60 mm thick beneath the bottom of the casing . The requirement
for insulation above the top of the casing is 150 mm . The thermal conductivity of the insulation must be
less than 0 .1 W/m x K (as measured at 200 ºC) .
Requirements for chimney and smoke pipe
The chimney must be of a sufficient height to enable an adequate draft and to prevent smoke problems .
The stove requires a draft of at least 12 Pa .
The chimney must have a minimum opening equivalent to Ø 150 mm .
The chimney opening should always be at least the size of the outlet socket of the insert .
The chimney must have an easily accessible soot door .
Smoke pipe and chimney must always be suitable for a stove connection . Ask your HWAM dealer for
more information .
Weight
7 .0 kW
275°C
5 .5 g/sec .
80 .7%
Height
92 kg
53,4cm
6
ENGLISH
Width
Depth
73,8 cm
47,0 cm