Speed
Torque (soft joint)
Impact speed
Ambient temperature for operation
Storage temperature
4.1
Battery
Battery operating voltage
Weight, battery
Ambient temperature for operation
Storage temperature
Battery charging starting temperature
4.2
Accessory tools – permissible diameters
Ø range of keyless chuck
Ø wood drill bits (hardwood)
Ø wood drill bits (softwood)
Ø drill bits for metal
Ø drilling in concrete/masonry (hammer-action
drilling)
5
Preparations at the workplace
WARNING
Risk of injury by inadvertent starting!
▶ Before inserting the battery, make sure that the product is switched off.
▶ Remove the battery before making any adjustments to the power tool or before changing accessories.
Observe the safety instructions and warnings in this documentation and on the product.
5.1
Charging the battery
1. Before charging the battery, read the operating instructions for the charger.
2. Make sure that the contacts on the battery and the contacts on the charger are clean and dry.
3. Use an approved charger to charge the battery. → page 6
8
English
SF 6-22
2nd gear
0 /min ... 2,000 /min
≤ 65 Nm
•/•
−17 ℃ ... 60 ℃
(1 ℉ ... 140 ℉)
−20 ℃ ... 70 ℃
(−4 ℉ ... 158 ℉)
SF 6-22
1.5 mm ... 13 mm
(0.06 in ... 0.5 in)
1.5 mm ... 20 mm
(0.06 in ... 0.8 in)
1.5 mm ... 32 mm
(0.06 in ... 1.3 in)
1.5 mm ... 13 mm
(0.06 in ... 0.5 in)
•/•
SF 6H-22
0 /min ... 2,000 /min
≤ 65 Nm
36,000 /min
−17 ℃ ... 60 ℃
(1 ℉ ... 140 ℉)
−20 ℃ ... 70 ℃
(−4 ℉ ... 158 ℉)
21.6 V
See the end of these
operating instructions
−17 ℃ ... 60 ℃
(1 ℉ ... 140 ℉)
−20 ℃ ... 40 ℃
(−4 ℉ ... 104 ℉)
−10 ℃ ... 45 ℃
(14 ℉ ... 113 ℉)
SF 6H-22
1.5 mm ... 13 mm
(0.06 in ... 0.5 in)
1.5 mm ... 20 mm
(0.06 in ... 0.8 in)
1.5 mm ... 32 mm
(0.06 in ... 1.3 in)
1.5 mm ... 13 mm
(0.06 in ... 0.5 in)
4 mm ... 12 mm
(0.2 in ... 0.5 in)
2275218