Operation & malfunction
Possible operations and malfunctions of the B'Safe vest regarding the B'Safe airbag:
If you notice any other malfunctions, please contact your dealer or our after sales
service via email sav@helite.com or by phone +33 3 80 35 48 26.
User Guide
System operational
Green flashing LED / No Beep
Low battery
Orange flashing LED / 4 Beeps
during airbag activation or deactivation
Battery charging
Orange LED / No Beep
Charging completed
Green LED / No Beep
when the charger is still connected
Pairing in progress
Blue LED / 1 Beep every 5 sec
(during 30 sec)
Success of pairing
Blue LED / 1 Beep of 2 sec
(2 short beeps when the sensor is already recognized)
Pairing failed
Red LED / 4 Beeps
(or too many sensors recognized by the vest)
Disconnected Cartridge
Red LED / 1 Beep every second
(while the cartridge is not connected)
You can cycle.
You need to recharge
the vest.
You can still ride
your bike for 2 hours.
Wait until the end of the
charging (Green LED).
Unplug the charger.
You have 30 sec to pair
the saddle sensor.
The vest and the saddle
sensor are paired.
Restart the pairing.
Plug the cartridge in.