FAILURE
Low battery tension
Voltage < 1.8V/cel
Deep discharged battery
(voltage <1,5V/cel)
Overheat
Battery over voltage
Short circuit in the outlet
Overload
Inversion of the battery polarity
Maintenance
The inverters of the ONS series do not need any special maintenance. The casing may be cleaned with a damp
cloth (not wet).
In the case of malfunction, the inverter should be sent back to the manufacturer for control in its original
packing.
Before sending the inverter, check the table above.
The battery is loaded and is in accordance to the inlet nominal tension of the device.
The consumer devices do not have any defects or overload for the inverter.
Should you contact your salesperson, note the following points before calling:
(you will find this information on the label underneath the inverter)
Series number
Power of the inverter
Inlet nominal tension of the inverter
So you will have quick and efficient help to solve your problem.
Warranty limit
The warranty will be considered void if the unit has suffered any physical damage or alteration, either internally
or externally, and does not cover damage arising from improper use like:
Reverse of battery polarity
Inadequate input voltage (over voltage)
Back-feed of the inverter output by public network , generator or any other source.
Mechanical shock or deformation especially by transport due to an unappropriate package.
Contact with liquid or oxidation by condensation
Use in inappropriate environment (dust, corrosive vapour, humidity, high temperature,...)
This warranty will not apply where the product has been misused, neglected, improperly installed, or repaired
by anyone other than ENAG or a company authorised by ENAG. In order to qualify for the warranty, the
product must not be disassembled or modified.
ONS1DED.doc
CONSEQUENCE
Inverter momentarily
stopped, the green indicator
blinks.
Inverter stopped
Inverter momentarily
stopped, the green indicator
blinks.
Inverter stopped.
Inverter stopped.
Inverter stopped.
Internal fuse broken down
SOLUTION
Automatic restart when the battery tension rises
Inverter should be manually restarted when the battery as
reach 2V/cel
Automatic restart when the temperature reaches the normal
range.
Wait until the battery tension reaches the correct level.
Push the ON/OFF switch to reactivate the inverter.
Eliminate the short circuit.
Push the ON/OFF switch to reactivate the inverter.
Use the inverter only in the range of its nominal power.
Regular use in overload power diminished the lifetime of the
inverter.
Push the ON/OFF switch to reactivate the inverter.
Back to manufacturer for testing