Télécharger Imprimer la page

TDK-Lambda DPP120 3 Série Mode D'emploi page 13

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 5
DPP120-xx-3
Product HANDBOOK
Special Safety Instructions
Standard Specific Safety Instructions:
Whilst all individual outputs are classed as SELV outputs in accordance with the standard
IEC/EN/UL/CSA60950-1 (<60Vdc or 42.4V peak), seriesed combinations of these outputs may exceed these
values and become hazardous output voltages.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the
equipment may be impaired.
Environmental Specifications:
Description
Operation
Storage
Use
Indoor
-
Temperature
-25° C - +71° C (derating at 2.5%/° C from 61° C)
-25° C - +85° C
Humidity
20 - 95% RH, non-condensing
20 - 95% RH, non-
condensing
Altitude
2000M
4850m (IEC60068-2-13)
Orientation
See Fig 1
ALL
Material Group
IIIb
Pollution Degree
2
Class
I
Level of Insulation:
Dielectric Strength testing is carried out as follows:
Primary mains circuit to earth: - 1500KVAC, 2121VDC
Primary mains circuits to secondary: 3kVAC, 4142VDC*
*This test is not possible with Y capacitors fitted to the unit as damage to these
capacitors will occur. It is also necessary to short circuit the output together and to earth.
Safety Approvals:
UL508
nd
UL/cUL60950-1 (2
Edition)
nd
IEC / EN60950-1(2
Edition)
CE marking when applied to any DPP120-xx-3 product indicates compliance with the Low Voltage Directive
nd
(2006/95/EC) in that it complies with EN60950-1 (2
Edition).
Fusing: Internal fuses (F1): Single fuse each phase, T2AH, 600V
Symbols:
N
L
AC
EARTH
N – Neutral
L – Live
If the earth terminal of the DPP120-XX-3 PSU is connected to the main incoming earth conductor of the end
equipment, the installer must cover the earth symbol with a label bearing the earth symbol of IEC60417-5019.
Page 13 of 16
DPP120-xx-3, XXXXX issue 02, April 2013

Publicité

loading

Ce manuel est également adapté pour:

Dpp120-12-3