The various wire guides are marked with numbers 1 to 4.
A: Union nut
B: FAR-Best.-Nr. 2000104272
FAR-Best.-Nr. 2000104274
FAR-Best.-Nr. 2000100801
FAR-Best.-Nr. 2000100852
9.3
Engage the wires (d) on the wire guides (e) according to their colours.
9.4
Cut off the projecting wire ends flush, i.e. without protrusions.
9.5
Push the union nut (c) onto the electrical T-distributor (f) and tighten it to the required
torque (1.2 Nm).
Caution!
Note the polarity.
The same wire colour must be in the same wire guide for both union nuts.
☞
When tightening the union nut, the electrical contact and tension relief are created
automatically.
Special seals act as protection from dust and water.
10. Assembly
Prepare the electrical connection
☞
The power supply should be installed in a separate room outside the wet area and
secured with a residual current device (RCD).
10.1 Install the cistern (a).
10.2 Install the electrical T-distributors (b, c) (see
10.3 Attach the motor (d) inside the cistern (see MBA 18-05.697).
10.4 Connect the motor (d) to the first electrical T-distributor (b).
10.5 Engage the pressure coil of the cistern (a) on the motor (d).
10.6 Use the adhesive tape to attach the electronic module (i) to the motor.
e: Actuator cable (motor)
f: Connection for the sensor to be provided by the customer (e.g. door contact or
trigger device for disabled persons)
g: Piezo button
h: Electrical T-distributor system cable (power)
i: Electronic module
10.7 Connect the actuator cable of the motor (d) to the actuator cable (e) of the electronic
module (i).
6
A
1
brown
2
white
3
blue
4
black
Chapter
9.).
B
red
white
blue
black