3. Installation
WARNING: Qualified personnel only
Instructions
1. Mount wall bracket (for top holding) of the battery charger,
make sure it is level.
2. Install three screws.
3. Open cover by removing four screws, on front bottom cover.
4. Put charger on mounting bracket and mark the Bottom of the
two (M6-D-holes) mounting holes.
5. Install M6 screws.
6. Install AC cord to input terminal strip marked E, N, L, be sure to
use the correct size wire (per ABYC regulations) to use for the
input current marked on the label of charger.
7. Cut DC inlet plugs to cable size, then connect battery cables to
DC lugs marked +DC & -DC. The -DC is used commonly for all
three batteries. If there are less than three batteries, pick any
+DC; all are capable of full current load. Select appropriate size
wire (per ABYC regulations).
8. Select battery type by pushing the appropriate DIP switch at
bottom left corner of board. Note: This unit is selected for GEL; if
you change battery type DESELECT GEL, (See Figure 1).
9. Replace top cover and reinstall four screws on cover.
10. Apply power and verify Green LED is on (bottom left of PC
board, look through bottom left air vents).