• Turn the F/R knob (G) to "F"or "R" position (F=Forward or R=Reverse).
• Adjust the regulator knob H to control the speed of the air flow.
• Press the trigger (B) to use the tool.
Before operating the equipment, put some oil drops (D) in the air inlet opening (F) of the pneumatic tool.
In case connection (E) is already assembled on the inlet opening (F), put some oil drops (D) on it (E).
Choose the correct impact socket (C) from the kit as needed and mount it onto the anvil (A).
Connect air supply hose to E.
Turn the F/R knob (G) counterclockwise to "F"position (F=Forward or Tighten).
Turn the F/R knob (G) clockwise to "R" position (R=Reverse or Loosen).
Press the trigger (B) to use the tool.
• The operator's fingers must not be close to the grinding stones when the machine is connected to the power source.
• When the grinding stone is not in contact with the surface release the trigger to stop the shaft.
• The rotation does not stops immediately.
Disconnect the air supply from the tool.
Check the chuck is not damaged and freed of debris.
Insert the correct tool according to chuck's diameter and lock by the mean of the open end wrench.
Ensure that the shaft is correctly installed and locked.
Squeeze the trigger for a few seconds and check the disc rotates without anomalous vibrations. Do not use the tool if
this occurs.
You are advised to lubricate the tool before each use.
Connecting the air using the quick coupling.
Adjust the operating pressure so that it remains within the operating pressure range specified for the tool.
Check that
the grinding stone correctly remove the material from the object. Do not press too much the stone onto
the surface in order to avoid excessive wear and dangerous damages.
Replace the tool when becomes ineffective ot the disc is worn in order to prevent dangerous disc
.
Disconnect the air supply during maintenance on the tool.
Regularly clean and dry the filter in the system and the pneumatic tool air inlet opening.
Lubricate any quick-disconnect coupling on the system to prevent jamming.
Drain condensation from air filter and from the compressor on a daily basis.
In order to avoid rust formation and to minimize wear, clean and lubricate the tool after each use.
Check the tool regularly on loose bolts/screws or parts.
In case of power loss: have the tool repaired.
Only trained and qualified engineers are allowed to adjust or repair the tool.
In case the tool is equipped with a silencer, make sure that this silencer is working properly, a damaged silencer has
to be replaced.
The tool should be maintained regularly to minimize the noise emission and occurring vibration.
If you intend not to use the tool for a longer period of time, it has to be oiled. Please fill some droplets of resin and
acid free oil into the air inlet and let the tool run free for a couple of seconds.
Maintain the tool at least yearly.
USING THE RATCHET WRENCH (2)
USING THE GRINDER (3)
MAINTENANCE
INTENDED USE