Replacing the ultraviolet lamp and the nano-mesh divider
This is how to replace the ultraviolet lamp and the nano-mesh divider:
➤ Unplug the device from the electrical outlet.
➤ Unscrew the four screws on the corners of the bottom side.
➤ Remove the cover.
➤ Let the device cool down for 5 minutes.
➤ Pull the ultraviolet lamp (fig. 1 3, page 3) out of the lamp socket
(fig. 1 5, page 3).
NOTICE!
A
Do not touch the new ultraviolet lamp with you bare hands as the
oil you leave on it will shorten its service life.
➤ Put the new Dometic ultraviolet lamp into the socket (fig. 1 5, page 3).
Insert the pins on the lamp firmly into the socket.
➤ Place a new maintenance sticker with the current date over the old one
so that you know when the ultraviolet lamp needs to be replaced.
➤ Lift the nano-mesh divider (fig. 1 2, page 3) out of the slots.
➤ Insert the new nano-mesh divider lengthways into the slots.
It does not matter which side faces the ultraviolet lamp.
➤ Clean the device if necessary (see chapter "Cleaning and caring for
Breathe Easy™" on page 27).
➤ Put on the cover.
➤ Fasten the cover with the four screws.
➤ Connect the device to the electrical outlet.
WARNING!
!
Eye damage may result from directly viewing the light produced by
these lamps. To reduce the risk of exposure to UV radiation, take
UV-radiation protective measures for personnel during servicing.
➤ Check that the ultraviolet lamp lights up.
You can see a blue glow through the vents.