Filling with electrolyte
Fill the battery with electrolyte (dilute sulphuric acid) with a density of 1,280.
Fill to the "upper level" as indicated on the battery.
The electrolyte temperature should not be more than 30°C (86°F) when filling.
Leave the battery standing for half an hour after filling.
Electrolyte level may fall during standing. Refill again to the "upper level".
First Charge
In order to optimize the life and power of your battery, an initial charge is highly recommended.
Charge the battery with a Motorcycle battery charger that suits for this size/type of battery
with an output current 1/10th of the battery's rated capacity.
Let the battery settle for 1 or 2 hours after charging before checking the voltage.
If the voltage is less than 12.8 volts, additional charging is necessary.
If the electrolyte level is found fallen has dropped after charging, fill with distilled water up to
the "upper level".
After charging replace the vents plugs firmly, wash off acid spillage with water, and dry the
battery.
INSTALLATION
Fasten the battery firmly to vehicle. Be sure not to wrongly connect battery's positive and
negative terminals.
Do not fold or crimp the battery's exhaust tube.
It may cause explosion if the tube is crimped.
6