AC INPUT VOLTAGE ....................................................................................................................... ±10% of rated line voltage
ALTITUDE .............................................................................................................................. Up to 7,500 feet above sea level
CONTROL OVERLOAD CAPACITY ............................................................................................................. 200% for 1 minute
DIMENSIONS & WEIGHTS:
ENGLISH
METRIC
DRIVE SERVICE FACTOR ..................................................................................................................................................... 1.0
EFFICIENCY ............................................................................................................................................................. 85% typical
ELECTRICAL SPECIFICATIONS - TYPICAL CURRENT & HORSEPOWER RANGES:
115VAC INPUT / 0-90VDC OUTPUT
H.P.
MAX AC AMPS
1/8
1.80
1/6
2.60
1/4
3.50
1/3
4.40
1/2
6.50
3/4
9.30
1.0
13.20
1.5
21.50
2.0
--------
3.0
--------
FUSE PROTECTION ................................................................................................................. 2 AC line fuses (see "Fusing")
HUMIDITY ................................................................................................................................................. 99% non-condensing
INPUT FREQUENCY ............................................................................................................................................ 50 or 60 Hertz
MAXIMUM ARMATURE CURRENT - CONTINUOUS ......................................................... 10 ADC (2 H.P.); 15 ADC (3 H.P.)
PILOT LAMP ("RE" VERSION) ........................................................................................................................................... Neon
POWER DEVICES ........................................................................................................................... Packaged full wave bridge
SHUNT FIELD VOLTAGE .......... 100VDC for 115VAC in; 200VDC for 230VAC in; (1.0 A max. - 530B; 1.5 A max. - 533B)
SPEED CONTROL ......................................................................... Via 5KΩ Ω Ω Ω Ω Potentiometer OR 0 to +10 VDC isolated signal
SPEED RANGE .................................................................................................................................................................... 50:1
SPEED REGULATION ................................................................................................................................. ±1% of base speed
TACHOMETER FEEDBACK ................................................................................ jumper selectable 3V or 7V per 1000 RPM
TEMPERATURE RANGE ............................................................................................. -10° to 45° C. ambient (15° to 115° F.)
TRANSIENT VOLTAGE PROTECTION ............................................................................................................................ G-Mov
TRIMPOTS:
ACCELERATION RANGE ................................................................................................... 0.3 to 12 seconds - adjustable
CURRENT LIMIT RANGE ......................................................................................................... 1 to 20 Amps (1/8 to 2 H.P.)
CURRENT LIMIT RANGE
DECELERATION RANGE ................................................................................................... 0.6 to 12 seconds - adjustable
I.R. COMPENSATION RANGE .................................................................................... 1/8 through 2.0 h.p. (530B controls)
I.R. COMPENSATION RANGE
MAXIMUM SPEED RANGE ..................................................................................................... 60% to 120% of base speed
MINIMUM SPEED RANGE ..................................................................................................... 0 to 30% of maximum speed
TYPE RAMP OF ACCEL / DECEL .................................................................................................................................... Linear

SPECIFICATIONS

WIDTH
LENGTH
6.70"
9.00"
6.70"
9.00"
6.70"
10.00"
171 mm
229 mm
171 mm
229 mm
171 mm
254 mm
MAX ARM AMPS
1.40
2.10
2.70
3.40
5.00
7.20
10.20
14.70
-------
-------
...................................................................................................... 2 to 30 Amps (1.5 and 3 H.P.)
............................................................................................. 1.5 and 3.0 h.p. (533B control)
DEPTH
WEIGHT
2.25"
2.25"
4.75"
51 mm
1134 gm.
57 mm
1162 gm.
121 mm
1422 gm.
230VAC INPUT / 0-180VDC OUTPUT
MAX AC AMPS
------
------
1.80
2.20
3.30
4.80
6.50
9.70
12.90
22.00
16
TYPE
40 oz.
C
41 oz.
RC
56 oz.
RE
C
RC
RE
MAX ARM AMPS
------
------
1.40
1.70
2.50
3.70
5.00
7.50
9.90
15.00