6 . D E S C R I P T I O N
A V R - F R O N T P A N E L
2
5
1
1 – Power switch: ON/OFF switch:
Always switch to ON mode during the use of the AVR
Always switch to OFF mode during installation and maintenance.
2 – Green LED: lighting when the AVR works properly
3 – Red LED: lighting when the AVR is malfunction or under protection
4 – Yellow LED: lighting or flashing when the AVR is in Delaying, by default the AVR is set
for 6 seconds delaying to take inductive or capacitive load such as compressor or motor
based equipments, select 180 seconds delaying time.
5 – Input Voltage Meter: by voltage meter or digital LED meter showing the input voltage.
6 – Output Voltage Meter: by voltage meter or digital LED meter showing the output
voltage
7 – Delay/ undelay Selector: Press to select the delay time of the AVR.
Setting delay time as 3 minutes. It's designed to avoid damage devices with AC motor from
consecutive starts. It's perfect to use with devices such as refrigerators, freezers, air
conditioners or dehumidifiers.
Setting delay time as 6 seconds. It's designed for use with voltage sensitive equipment such
as: personal computers, monitors, inkjet printers, scanners or faxes. It's also designed for
use with home appliances such as televisions, stereos, CD/DVD players, VCRs, modems,
and telephone equipment.
INFOSEC UPS SYSTEM – 15, rue du Moulin - 44880 Sautron - FRANCE - www.infosec-ups.com
Hot Line – Tel + 33 (0)2 40 76 15 82 - Fax + 33 (0)2 40 94 29 51 - hotline@infosec.fr – 11 16 AA XX 203 01
6
3
4
7
5