Creating a job in 4 steps
NOTE
For devices with interchangeable
EN
lenses, the image focus is set on
the installed lens.
14 14 EN
Launch of opti-check Application Suite
Choose your device in the selection list. With
button, you connect with the selected opti-check.
The display shows either Live images from the opti-
check or Images from PC (example images). Select the
image source you require.
Use the Start image series button if no live image is
shown.
1.
Adjusting an optimum image
To implement reliable inspection with the opti-check, the
features to be inspected must be clearly visible.
Set the image focus with an inbus key on the opti-check
installed at the testing site. The corresponding inbus
screw can be found on the LED panel.
Check focus (device dependent):
Use the Focusing tab.
Set the trigger to
CONTINUOUS IMAGE CAPTURE
Enter the speed of the object and the distance to
object between the device and the object (see page 12,
Mechanical setup). The Application Suite calculates the
corresponding parameters automatically.
Manual fine adjustments of image brightness can be
made with the slider bar
image so that the object is seen to be bright enough
without the need to override.
. Adjust the
EXPOSURE TIME
CONNECT
.