Télécharger Imprimer la page

CDVI NANOPW Mode D'emploi page 4

Masquer les pouces Voir aussi pour NANOPW:

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION MANUAL
NANOPW - NANOPB
Wiegand 125 Khz proximity reader
5] WIRING DIAGRAM
Card Swiped
- Badge recognized: the orange LED illuminates and the buzzer activates for 150 milliseconds.
Wiegand output formats
DIP1
DIP2
OFF
OFF
ON
OFF
OFF
ON
Buzzer activated or not after badge recognised :
By default the buzzer is activated in standard mode.
To inhibite the buzzer :
- Power Off the NANO
- Connect the brown wire with the black wire
- Power On the NANO
- As soon as the buzzer beep, disconnect the brown wire
Now the buzzer is not activated after badge recognised.
The brown wire can be connected to the output of the access unit and be activated or not.
To enable the buzzer :
- Power Off the NANO
- Connect the brown wire with the black wire
- Power On the NANO
- As soon as the buzzer beep, disconnect the brown wire
Now the buzzer is activated after badge recognised.
The brown wire can be connected to the output of the access unit and be activated or not.
4
cdvigroup.com
Cable
Red
Input voltage 12V dc
Black
0V
1
2
ON
Blue
Clock
Green
Data 0
OFF
White
Data 1
Brown
Buzzer
Yellow
Green LED
Orange
Red LED
BITS
26
30
44
When powered
- Green LED illuminates for 1 second
- Red LED illuminates for 1 second
- Buzzer sounds for 1 second
Operating mode
- Buzzer activated with 0V input
- LEDs activated with 0V input
Green LED
Red LED
OFF
OFF
OFF
ON
ON
OFF
ON
ON
EN
Status
OFF
red
green
blue

Publicité

loading

Ce manuel est également adapté pour: