Temperature (°C)
3.2
Display messages
The Expert Modular can show a number of different status messages on the display. These will vary from
advisory- to error messages. Please see the table below for the available messages
Table 4
Message
'<battery name> Battery Full'
'Low Voltage'
'High Voltage'
'Low Battery'
'Low Time Remaining'
'High Charge Current'
'High Discharge Current'
'Low Temperature'
'High Temperature'
'High Midpoint Deviation'
1)
The number inside the battery icon indicates to which battery the message applies
3.3
Synchronization
The Expert Modular is a true next generation battery monitor that does not specifically require a full
synchronization before you can actually use it (except for LiFePO4 batteries). The smart internal
algorithms can already estimate the state of charge by performing a short battery analysis at start
up. Unlike many other battery monitors on the market, the Expert Modular will not get out of sync
easily when the battery is not being fully charged (synchronized) very often.
Nevertheless, for the highest State of Charge (SoC) readout accuracy, it is still advisable to regularly
synchronize the Expert Modular with your battery. A synchronisation step means nothing more than
performing a complete charge cycle on your battery. The Expert Modular will automatically detect
when a full charge cycle has been performed and resets the SoC value to 100%.
Performing full charge cycles regularly is also important to keep your battery healthy and to increase
its lifetime.
Shows the battery temperature when a temperature sensor is
connected to the Expert Modular. The default temperature
unit is °C, but it can be set to °F as well in Function F10.3.
Explanation
The main battery is fully charged. '<battery name>' will
be replaced by the name given in Function 1.7
Low battery voltage alarm
High battery voltage alarm
Low main battery State of Charge (SoC) alarm
Low time remaining alarm for main battery
High charge current alarm for main battery
High discharge current alarm for main battery
Low temperature alarm for main battery
High temperature alarm for main battery
High midpoint deviation alarm for main battery