Single-phase panel with power adjustment. Luminous inlet indicators. Outlet to activate soundless electric lock.
Optional smooth stop. Radio incorporated with possibility of 253 different channels.
Possibility of digitally programming times (the operating time potentiometer must be at a minimum for the panel to
operate with digital times).
Installation.
Make sure that the power is disconnected before proceeding with installation.
Description Bornes.
Power
Operation
1 220Va.c feed
8 Outlet 12V dc 125mA
2 220Va.c feed
9 O V (common pedestrian)
3 Motor opening
10 Pedestrian opening button.(N.A.)
4 Motor closing
.
11 Common contact limit switch.
5 Common motor
12 Closing limit switch N.C.
6 Voltage-free garage light
13 Opening Limit switch N.C.
7 Voltage-free garage light
14 Safety Contact (NC)
15 Common for buttons
16 Start button N.O.
N.B: N.O., Normal Opening
17 Electric Lock 12 V
N.C., Normal Closing
18 Electric Lock 0 V
Selection of Options.
Select the options with micro-switches.
I 1 Automatic closing
ON: The door closes automatically when the time programmed with the
potentiometer has passed.
OFF: No automatic closing.
I 2 Inversion stroke
ON: Leave the door for 3 seconds before giving the order to open
(1)
OFF: Door opens normally.
I 3 To stop closing
ON: If the start button is pressed the door will not open
OFF: If the start button is pressed when the door is opening
it will stop.
I 4 Photocell closing
ON: If the photocell is enabled when the door is opening or is
(2)
open it will give the order to close.
OFF: The photocell will not give the order to close.
I 5 Smooth stop
ON: The door will close smoothly for the last 7 seconds of the operation.
OFF: No smooth stop.
(1). If switch I2 is ON, the panel will order maximum power for 3.5 seconds on completing the closing operation to
make sure the door is closed properly.
(2). If the panel is operating with digital times, switch I4 is also used for selection if times ( I4 ON) or transmitters (
I4 OFF) are to be programmed with the programming button.
TIMERS.
Automatic Closing Time .
Working Time.
T.BAJ.AUT.
T.FUNC.
3 seg
120 seg
3 seg
(Mark between FCC-FCA (11) and FCC (12) if not in use)
(Mark between FCC-FCA (11) and FCA (13) if not in use.)
(Mark between C.SEG (14) and Mass (15) if not in use.)
Motor Power.
FUERZA
60 seg
Less
More
ENG
Digital Adjustment of operating times, automatic close and smooth stop.
Before starting to programme the times, disconnect from the mains and ensure that:
All the connections have been made correctly.
All the options switches are OFF except for I4 that must be ON.
The door is fully closed.
If you want smooth stop at the end of the operation, turn I5 to ON
Once the above points have been reviewed, connect the circuit to the mains and start programming the opening,
automatic close standby and closing times. To do so, proceed as follows:
Press the programming button until the programming led comes on. The led will flash while the times are being
programmed.
2.A Enable the start button using the transmitter or the test button. The door will begin to open.
2.B If you require the 'smooth stop' option, I5 must be ON. Wait for the door to open past the point where the
'smooth stop' is to begin and then press the start button or the remote control and the motor buffering will begin.
The opening buffering time will be memorised.
Once the required opening point is reached, stop the door by pressing the start button or wait for it to stop
automatically if the opening limit switch is connected.
The standby time for automatic close will then begin to be counted. After the required time, press the start button
again and the door will begin to close.
5.A If you require the 'smooth stop' option, I5 must be ON. Wait for the door to close past the point where the
'smooth stop' is to begin and then press the start button or the remote control and the motor buffering will begin.
The closing buffering time will be memorised.
Once the door has closed, press the start button again or wait for the door to stop automatically if you have the
closing limit switch connected. The programming led will switch off and programming will be complete.
Operating
a)
Normal operating.
Automatic operations are carried out using the start button (button TEST C.I. plaque, P.ALT terminals button or with the
radio card.
The operation stops in either of the following conditions: the pressing of the corresponding FC or completing of the
operating period.
If an order is given during the opening operation the operation will end and the door will not close automatically.
If an order is given during the closing operation this will inverted and the door will open.
Pressing C.SEG during the closure operation will invert the operation, opening the door.
The Garage Light Contact enables the start of the opening operation and disables 2 seconds after the start.
The power adjustment of the motor selected using the POWER switch is applied 2 seconds after the start of the
operation.
b)
Pedestrian Opening
If the door is completely closed it can be partially opened for pedestrians using button P. Open. The door will open for a
period of 5 seconds.
Memory code channel
The control panel should be in a stable position, door open or closed, to memorise the channel codes.
a) Memory manual
To memorise a code, press programming button PROG/RES for 1.5 seconds. The red Led will come on and will remain
lit, indicating preparation to memorise the code.

Publicité