6. DC output Voltage status & control
This area monitors DC output voltage, and allows you to tune +12V output voltage, and
OVP warning point by clicking + or – buttons. The voltage/warning adjustable range is
described in table B.
Adjustable output range
+3.3V
+5V
+12V
11.64~12.36V (±3%)
7. AC input status
This area monitors AC input Voltage range, input current, wattage and Power Factor
value.
8. Additional Information tab
1) Reset
Clicking "Reset" will set all settings back to the default profile.
2) Product Information
Clicking "Product Information" will show the PSU model number and ZDPMS
software version.
3) Save option
Clicking "Save" allows you to save the PSU input, output data and the current
settings as *.txt file.
4) Usage option
Clicking "Usage" tracks the operation time from when ZDPMS software started.
Entering your local average electricity fare ($/ KwH) to estimate the electricity cost
since the monitoring software initiated.
Table B: Voltage control range
Adjustable warning point range
-
-
3.45~3.7V
5.2~5.7V
12.4~13.1V
5

Publicité