Télécharger Imprimer la page

Aqua Medic mV computer Mode D'emploi page 7

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
8.
Set up for controlling the ORP with an Ozonizer
The redox probe is placed in the aquarium at a dark and well-circulated place. The ozonizer is connected to the
mV computer (connection plug, 4) and the set point is adjusted as described, e. g. at 400 mV. The air is produced
by a membrane air pump, pressed through the ozonizer and directed into the protein skimmer. Here, the small
bubbles produce the foam and remove the organics with the aid of ozone. If the desired ORP value in the
aquarium is reached, the ozonizer is switched off. Take care that all ozone is used in the protein skimmer and
no residual ozone escapes into the air or water. It can be detected by its strong smell.
9.
Electrode
The Aqua Medic electrode is specifically designed to determine the redox-potential in fluid based solubles. It can
be used in the chemical industry, medical areas and in research laboratories.
9.1. Technical Data
Measurement range:
Sample temperature:
Connection:
Material:
9.2. Measurement/Maintenance
-
During the measurement, the platinum tip must be continuously submerged in the solution.
-
A new probe or one which has been dry for a longer period must lay in water for at least 24 hours.
10.
Failures
-
The unit indicates false values --> clean the probe.
-
The redox-potential probes have a limited lifespan (1 - 3 years).
11.
Warranty conditions
AB Aqua Medic GmbH grants the first-time user a 24-month guarantee from the date of purchase on all material
and manufacturing defects of the device. Incidentally, the consumer has legal rights; these are not limited by
this warranty. This warranty does not cover user serviceable parts, due to normal wear & tear i.e: impellers or
drive wheels etc. The original invoice or receipt is required as proof of purchase. During the warranty period,
we will repair the product for free by installing new or renewed parts. This warranty only covers material and
processing faults that occur when used as intended. It does not apply to damage caused by transport, improper
handling, incorrect installation, negligence, interference or repairs made by unauthorized persons. In case of
a fault with the unit during or after the warranty period, please contact your dealer. All further steps
are clarified between the dealer and AB Aqua Medic. All complaints and returns that are not sent to
us via specialist dealers cannot be processed. AB Aqua Medic is not liable for consequential damages
resulting from the use of any of our products.
AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany
7
1,000 - + 1,000 mV
5 – 60 °C, short-term
BNC-plug
Plastic shaft, Polysulfone, platinum tip
- Technical changes reserved – 02/2019

Publicité

loading