5.3 Electromagnetic Lock Connection
Door Lock Controlled with Internal Power
Note:
1.
Electromagnetic lock of Power-off-to-unlock type should be used.
2.
The door lock is limited to 12V, and holding current must be less than 250mA.
3.
The door lock control is not timed from Exit Button(EB).
4.
The
Unlock Mode
1 2 3
Jumper position in
BUS
PL
EB
*
5.4 Door Lock Controlled with Dry Contact
Note:
1.
The external power supply must be used according to the lock.
2.
The inside relay contact is restricted to AC or DC 24V/3A.
3.
The jumper must be taken off before connecting.
4.
Setup the
Unlock Mode
‡ Power-on-to-unlock type:Unlock Mode=0 (by default)
‡ Power-off-to-unlock type:Unlock Mode=1
-
8
-
Parameter of Monitor must be set to 1 (by default).
Connect one lock
2-3
S1
S2
S-
+
+
of Monitor for different lock types.
1 2 3
Connect two locks
Jumper position in
BUS
*
EB
2
nd
*
EB
1
ST
LOCK
2-3
PL
S1+
S2+
S-
LOCK
LOCK
2
nd
1
ST