Chapitre 6
Configurer le WAP Stratix 5100 en utilisant l'interface de ligne de commande
202
encapsulation dot1Q 20
no ip route-cache
bridge-group 20
bridge-group 20 subscriber-loop-control
bridge-group 20 block-unknown-source
no bridge-group 20 source-learning
no bridge-group 20 unicast-flooding
bridge-group 20 spanning-disabled
!
interface Dot11Radio1
no ip address
no ip route-cache
!
encryption vlan 20 mode ciphers aes-ccm
!
ssid wpa2_psk_ssid
!
speed basic-6.0 9.0 basic-12.0 18.0 basic-24.0
36.0 48.0 54.0
rts threshold 2312
station-role root
bridge-group 1
bridge-group 1 subscriber-loop-control
bridge-group 1 block-unknown-source
no bridge-group 1 source-learning
no bridge-group 1 unicast-flooding
bridge-group 1 spanning-disabled
!
interface Dot11Radio1.20
encapsulation dot1Q 20
no ip route-cache
bridge-group 20
bridge-group 20 subscriber-loop-control
bridge-group 20 block-unknown-source
no bridge-group 20 source-learning
no bridge-group 20 unicast-flooding
bridge-group 20 spanning-disabled
Pour les instructions dans Device Manager, voir
la sécurité réseau avec Easy Setup, page
Publication Rockwell Automation 1783-UM006B-FR-P– Janvier 2015
Limitations de configuration de
62.