USE
When the dehumidify mode is set to "CO" the dehumidifier will
continue to operate regardless of the humidity level.
When the dehumidifier is set to a required humidity level the
compressor and fan will run if the indoor humidity level is higher
or equal to 3% or more of the set humidity. After the humidity in
the room drops below 2% of the set humidity level, the
compressor is turned off and the dehumidification stops. The ok
indicator lamp will turn on. If the dehumidifier stops dehumidifying
and the room humidity rises above or equals 3% or more of the
set humidity, the compressor starts dehumidifying again. Note
that the compressor will only work again after the protection
status of three minutes has expired. The indoor humidity is
maintained at the set humidity level by the above cycle operation.
Comfort "AU" function
Between 5°C and 20°C room temperature, the automatic
selection is set to 60% humidity.
Between 20°C and 27°C room temperature, the automatic
selection is set to 55% humidity.
If the room temperature is above 27°C the humidity is set to
50%.
The dehumidifier stops working when the room temperature
comes below 5°C.
Laundry mode, with this function enabled, the dehumidifier will
continue to operate (compressor, fan operation) regardless of the
humidity level. The fan speed is locked at high speed and cannot
be adjusted.
Fan mode, The compressor does not work. The fan can choose
two operating modes: high fan speed and low fan speed.
Humidity setting button cannot be pressed in fan mode.
Full water protection, the dehumidifier will stop working when the
water tank is full, the full indicator will go on and the machine will
make an alarm sound. By pressing any key the alarm sound will
stop immediately. Please empty the drainage tank, see "Empty
the water tank" section. After emptying the water tank the original
machine's operating status is restored. (Note that the compressor
will only work again after the protection status of three minutes
has expired.)
Defrost function, when the machine turns automatically into the
defrosting mode, the compressor is turned off, the fan is
defrosted by high winds and the defrost indicator will go on. To
protect the dehumidifier and remove more water from the air, the
dehumidifier must sometimes stop cooling to melt the ice. A
sensor detects the formation of ice, activates a switch that turn off
the compressor. The fan keeps running so that the air flow from
the room can pass and help with the defrosting process. Once
the defrosting process has finished the original machine's
operating status is restored. (Note that the compressor will only
work again after the protection status of three minutes has
expired.)