Do not connect hot water piping directly to the copper piping. It
must be equipped with a dielectric connection (supplied with the
appliance).
In the event of corrosion of the threads of the hot water sprinkler
not equipped with this protection, our guarantee could not be
applied.
ELECTRIC CABLING
Before removing the cover, always make sure that the power is
turned off, to prevent any risk of injury or electric shock.
There must be an omni-polar power cut-off (circuit-breaker or fuse)
fitted upstream of the electrical installation, compliant with local
rules in force (30mA differential circuit-breaker). The system must be
earthed. A special terminal, marked
, is provided for the purpose.
French law strictly forbids connection of a product fitted with a cable
and plug.
MAINTENANCE - REPAIR
Drainage: Cut the power and cold water supplies, open the hot water
valves then operate the safety unit's drain valve.
The drainage device has a pressure limiting device that must be
operated regularly to remove any scale deposits and check it is not
blocked.
If the power cable is damaged, the manufacturer, the after-sales
service or similarly qualified people must replace it, for safety's sake.
This manual is also available from the customer service department
(contact details shown on appliance).