Installation notes

EN
3
Installation notes
Observe the safety and warning information in these
X
X
operating and installation instructions, as well those of
the BORA cooktop extractor (see section Safety).
3.1

Checking the scope of delivery

Name
ULS plinth fan
Installation notes
Sealing tape – plinth fan
Tab. 3.1
Scope of delivery
Check the scope of delivery for damage and make sure
X
X
it is complete.
If there are any missing or damaged parts, please
X
X
notify BORA After Sales Service.
Do not under any circumstances install parts which are
X
X
damaged.
Dispose of transport packaging in the proper manner
X
X
3.2

Installing the plinth fan

INFO The floor unit must not be supported on the plinth
fan housing.
Prepare the plinth fan by attaching the sealing tape
X
X
depending on the installation situation.
Secure the sealing tape to the inlet nozzle.
X
X
Fig. 3.1
Sealing tape position for installation with a round duct

3.2.1 Freestanding installation

Clean any major dirt from the supporting surface.
X
X
Position the plinth fan in the intended installation position.
X
X
Ensure that the plinth fan is securely positioned on all
X
X
4 feet.
Make sure that the connection cables are accessible.
X
X
3.2.2 Removing the inlet nozzle for
installation purposes
You can remove the plinth fan's inlet nozzle from the fan
housing for installation purposes.
8
Quantity
Fig. 3.2
1
Unlock the inlet nozzle by turning it to the left.
X
X
1
Lift the inlet nozzle up off the fan housing.
X
X
1
Position the plinth fan in the installation position.
X
X
Place the inlet nozzle on the fan housing.
X
X
Lock the inlet nozzle by turning it to the right.
X
X
The end positions when unlocking and locking the inlet
Q
Q
nozzle are specified by an end stop.

3.2.3 Suspended installation

If the plinth fan is installed suspended, the fixing
Q
Q
material must be made available at the installation
site in accordance with the building material.
Hand-tighten the fixing nut and secure it against
X
X
coming loose.
Secure the plinth fan to the three mounting straps
X
X
prepared on the housing.
The connection cables must be secured with the cable
X
X
routing clip provided.
3.3
Connecting the plinth fan to the
universal control unit
Fig. 3.3
[1]
Plinth fan connection plug control line
[2]
Plinth fan connection plug power supply cable
Connect the fan's control line [1] to the universal
X
X
control unit.
Connect the fan's power supply cable [2] to the
X
X
universal control unit.
Check the plug connections to ensure that they are
X
X
secure.
Make sure that the cable is not damaged.
X
X
Verify that the installation was done correctly.
X
X
Removing the inlet nozzle