Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Manuel d'utilisation
Instructions for use
Manual de instrucción
C
o
f
f
C
o
f
f
M
ó
d
u
l
o
M
ó
d
u
l
o
Version mai 2007
r
e
t
d
e
c
r
e
t
d
e
c
C
o
n
t
r
o
C
o
n
t
r
o
d
e
c
o
d
e
c
o
M
O
D
M
O
D
o
m
m
a
o
m
m
a
l
u
n
i
t
l
u
n
i
t
n
t
r
o
l
/
m
n
t
r
o
l
/
m
Y
S
Y
S
33502023501_0_1
n
d
e
n
d
e
a
n
d
o
a
n
d
o

Publicité

Table des Matières
loading

Sommaire des Matières pour SDMO MODYS

  • Page 1 Manuel d’utilisation Instructions for use Manual de instrucción ó ó Version mai 2007 33502023501_0_1...
  • Page 3: Table Des Matières

    1. Présentation du MODYS 1.1. Présentation Le MODYS est un module de contrôle / commande destiné à la conduite du groupe électrogène. Ce module est alimenté en 12 V ou 24V courant continu. Fig. 1.1 – Présentation du MODYS 33502023501_0_1...
  • Page 4: Conditions D'utilisation

    1.3. Conformité aux exigences légales et réglementaires Le module MODYS est conforme aux directives et normes ci-dessous : Directive basse tension 73/23/CEE et norme associée EN 60950-1: 2006. Directive compatibilité électromagnétique 89/336/CEE et normes associées EN 61000-6-2 et EN 61000-6-4 (émission et immunité)
  • Page 5: Présentation De La Face Avant

    2.1.1 Présentation de la face avant Fig. 2.1 - Présentation de la face avant Commutateur à clé de mise sous/hors tension du module et fonction RESET ; Bouton START permettant sur une impulsion de démarrer le groupe électrogène ; LEDs de visualisation des défauts. Fig.
  • Page 6: Présentation De La Face Arrière

    2.1.2 Présentation de la face arrière Fig. 2.3 – Présentation de la face arrière Connecteur 9 points avec entrées / sorties (B1…B9) - raccordement des équipements électriques Connecteur 2 points avec entrées / sorties (B10 / B11) – lecture tension / fréquence. Liste des entrées / sorties : Connecteur 9 points : Entrées / sorties...
  • Page 7: Emplacement De L'interrupteur De Changement De Fréquence

    2.1.3 Emplacement de l'interrupteur de changement de fréquence L’interrupteur de changement de fréquence 50/60 Hz est situé en dessous du module de contrôle. Il permet de régler la valeur de la fréquence nominale. La valeur de réglage par défaut est de 50 Hz. Fig.
  • Page 8: Utilisation

    Connecter la batterie du groupe électrogène ; Tourner le commutateur à clé sur la position Le module MODYS est sous tension. Toutes les LEDs s’allument pendant 2 secondes, ce qui permet de vérifier leur bon fonctionnement Appuyer d’une seule impulsion franche sur le bouton vert «...
  • Page 9: Arrêt Du Groupe Électrogène

    3.2.2 Disparition de l'ordre extérieur (avec option inverseur N/S) Sur un retour secteur (contrôlé par l’inverseur SDMO), l’ordre extérieur disparaît, le contacteur « secours » s’ouvre et le contacteur « normal » se ferme. A la disparition du signal, l’entrée de l’ordre extérieur bascule de l’état 1 à 0, le décompte (1 minute) de la temporisation de retour secteur (TRS) commence.
  • Page 10: Démarrage Sur Ordre Extérieur (Sans Option Inverseur N/S)

    Connecter la batterie du groupe électrogène ; Tourner le commutateur à clé sur la position Le module MODYS est sous tension. Toutes les LEDs s’allument pendant 2 secondes, ce qui permet de vérifier leur bon fonctionnement. Apparition de l’ordre extérieur : L’entrée de l’ordre extérieur bascule de l’état 0 à...
  • Page 11: Particularités

    5. Particularités • Arrêt d’urgence : Si le shunt du bornier B11 est enlevé (intérieur du pupitre), le groupe électrogène s’arrête instantanément en défaut d’arrêt d’urgence. Ce connecteur 2 points est destiné au branchement de l’arrêt d’urgence extérieur (capot ou local groupe). •...
  • Page 13 5. Special Note ....................................9 6. Troubleshooting ..................................9 1. Introduction to MODYS 1.1. Introduction MODYS is a command / control module designed to control the generating set. The module is powered by 12V or 24V DC. Fig. 1.1 – View of MODYS 33502023501_0_1...
  • Page 14: Operating Conditions

    LEDs to indicate faults and an LED for normal operation. on the rear side: 2 9-pin and 3-pin connectors for the electrical connection of the generating set to the MODYS module. underneath: a switch to adjust the value of the nominal frequency (50/60 Hz); this value will depend on the type of network used.
  • Page 15: View Of The Front Panel

    2.1.1 View of the front panel Fig. 2.1 - View of the front side Key switch for starting up/shutting down the module and RESET function; START button, press to switch on the generating set; Fault indicator LEDs. Fig. 2.2 – Description of the LEDs A lit LED indicates: Overspeed fault (red, continuously lit) Underspeed fault (red, flashing) or non-start fault (red, continuously lit)
  • Page 16: View Of The Rear Panel

    2.1.2 View of the rear panel Fig. 2.3 – View of the front side 9-pin connector with inputs / outputs (B1…B9) - connection of electrical equipment 2-pin connector with inputs / outputs (B10 / B11) – voltage / frequency measurement. List of inputs / outputs: 9-pin connector: Inputs / outputs...
  • Page 17: Position Of The Frequency Change Switch

    2.1.3 Position of the frequency change switch The 50/60 Hz frequency change switch is located below the control module. It makes it possible to adjust the nominal frequency. The default adjustment value is 50 Hz. Fig. 2.4 – View from below 33502023501_0_1...
  • Page 18: Use

    Connect the generating set battery; Turn the key switch to the N position; The MODYS module is on. All of the LEDs light up for 2 seconds, to confirm that they are operating correctly. Press the green “ T ” button once firmly;...
  • Page 19: Stopping The Generating Set

    Connect the generating set battery Turn the key switch to the ON position The MODYS module is on. All of the LEDs light up for 2 seconds, to confirm that they are operating correctly Appearance of the remote order - The remote order input changes status from 0 to 1 The countdown for the TMC delay (Micro Disconnection delay of 2 seconds) will start.
  • Page 20: Start-Up From Remote Order (Without Optional N/E Inverter)

    Turn the key switch to the N position; The MODYS module is on. All of the LEDs light up for 2 seconds, to confirm that they are operating correctly. Appearance of the remote order: The remote order input changes status from 0 to 1 The countdown for the TMC delay (Micro Disconnection delay of 2 seconds) will start.
  • Page 21: Special Note

    5. Special Note • Emergency stop: If the shunt on terminal block B11 is removed (inside the control console), the generating set stops immediately due to an emergency stop fault. This 2-pin connector is used for connecting the external emergency stop (cover or set site). •...
  • Page 23 6. Localización de averías menores ...............................9 1. Presentación del MODYS 1.1.Presentación El MODYS es un módulo de control/mando que sirve para manejar el grupo electrógeno. Este módulo funciona con corriente continua de 12 V o de 24 V. Fig. 1.1 – Presentación del MODYS...
  • Page 24: Condiciones De Uso

    2 conectores de tipo 9 puntos y 3 puntos para la conexión eléctrica del grupo electrógeno al módulo MODYS. parte de abajo: un interruptor que permite regular el valor de la frecuencia nominal (50/60 Hz); este valor depende del tipo de red utilizada.
  • Page 25: Presentación De La Cara Delantera

    2.1.1 Presentación de la cara delantera Fig. 2.1 - Presentación de la parte delantera Conmutador de llave de encendido/apagado de la tensión del módulo y función RESET; Botón START que permite activar el grupo electrógeno mediante una pulsación; Indicador luminoso de visualización de fallos. Fig.
  • Page 26: Presentación De La Cara Trasera

    2.1.2 Presentación de la cara trasera Fig. 2.3 – presentación de la parte trasera Conector de 9 puntos con entradas/salidas (B1…B9) - conexión de los equipamientos eléctricos Conector de 2 puntos con entradas/salidas (B10/B11) – lectura de tensión/frecuencia. Lista de entradas/salidas: Conector de 9 puntos: Entradas/Salidas Tipos de entradas/salidas...
  • Page 27: Ubicación Del Interruptor De Cambio De Frecuencia

    2.1.3 Ubicación del interruptor de cambio de frecuencia El interruptor de cambio de frecuencia 50/60 Hz está situado debajo del módulo de control. Éste permite ajustar el valor de la frecuencia nominal. El valor de ajuste por defecto es de 50 Hz. Fig.
  • Page 28: Uso

    Conecte la batería del grupo electrógeno; Gire el conmutador de llave para colocarlo en la posición El módulo MODYS tiene tensión. Todos los indicadores luminosos se encienden durante 2 segundos para comprobar el buen funcionamiento. Pulse sólo una vez hasta el fondo el botón verde "...
  • Page 29: Parada Del Grupo Electrógeno

    3.2.1 Arranque por orden exterior (con inversor normal/emergencia (N/E) opcional) El MODYS no controla las órdenes de apertura y cierre del inversor N/A. En este caso, y si el inversor N/A no es de SDMO, éste debe poseer su propio mecanismo de control de los elementos de conmutación N/A.
  • Page 30: Arranque Por Orden Exterior (Sin Inversor N/E Opcional)

    Conecte la batería del grupo electrógeno; Gire el conmutador de llave para colocarlo en la posición El módulo MODYS tiene tensión. Todos los indicadores luminosos se encienden durante 2 segundos para comprobar el buen funcionamiento. Aparición de la orden externa La entrada de la orden externa cambia del estado 0 al 1.
  • Page 31: Particularidades

    5. Particularidades • Parada de emergencia Si se desactiva el derivador de la regleta de bornes B11 (interior del cuadro), el grupo electrógeno se para instantáneamente e indica un fallo de parada de emergencia. Este conector de 2 puntos sirve para conectar la parada de emergencia externa (cubierta o local grupo).