4.2. The central unit does not stop
1. Stop the central unit
by pressing the OFF
button
YES
2. - Disconnect the central unit from the network
- Start the central unit by pressing the ON
button
- Block the vacuum inlet manually (as in the
diagram opposite)
The central
unit stops
Localised leaks in the ductwork
or on the accessories
3. - Connect the hose to the central
unit, which is disconnected from
the network
- Use the STOP button on the handle
to stop the central unit
The central
unit stops
NO
- Have you had a thunderstorm recently?
- Electrically disconnect then reconnect your central
unit, then try again
- If the problem persists, contact your Aldes After-
Sales Service
The central unit
does not stop
There are leaks in the central unit
- Check that the central unit's cover is correctly closed
- Check that the tank is positioned correctly
- If the problem persists, contact the Aldes After-Sales
Service
The central unit
does not stop
There are leaks in the accessories
- Check that the handle functions correctly
- Check that the hose has not been pierced