Technical Repair Guide
10

BASIC SERVICE GUIDE

The Basic Service Guide should cover most performance issues.
If after checking the items listed, the air cleaner still fails to
operate properly please contact your distributor.
Condition
Air cleaner inoperable.
Poorly operating or malfunctioning
remote control.
Fan fails to rotate.
Fan works but the air cleaner
functions poorly or not at all.
Crackling sound from the electronic
filter.
The air cleaner cannot be
controlled manually.
led blinks.
STANDBY
•••• and • leds blink.
The fan speed does not increase
when using the Air Quality
Analyzer.
The Air Quality Analyzer starts
while the atmosphere is apparently
clean.
Smells are no longer adsorbed.
0508082120/101203/C
Possible cause
Malfunctioning safety switch.
Disconnected from power.
Faulty cord or plug.
Faulty hardware and/or software.
(Nearly) exhausted battery.
Defective fan.
Faulty hardware and/or software.
One or more filters are polluted.
Vents are closed.
Dirt in the electronic filter causes a short-circuit
(
led blinks)
STANDBY
Electronic filter dirty or wet.
Missing prefilter.
Control is locked out.
Dirt in the electronic filter causes a short-circuit.
Short-circuit in the electronic filter by a broken
ionizing wire and/or bent collector plates.
Air cleaner is in PROGRAM mode.
The Service Indicator indicates that the filters are
clogged.
Fan speed limited.
Sensor reacts to, for instance, high or low humidity
or fumes from cleaning agents.
Air Quality Analyzer is too sensitive.
Activated carbon filter or Odor Free filter is
saturated.
Page 10
Solution
Properly close the extraction grid or contact your
service person.
Reconnect power.
Distributor to replace the cord or plug.
Contact your distributor for replacement parts.
Check the red led above the
remote control by pressing any button. Replace the
battery if the led is not activated.
Contact your distributor for replacement parts.
Contact your distributor for replacement parts.
Replace or clean the filters.
Open one or more of the vents (see section 5).
Clean the electronic filter.
Clean or dry the electronic filter.
Install prefilter.
See Program Setting # 4 (page 7) to unlock.
Clean the electronic filter.
Contact your distributor.
Push the PROGRAM button on the remote control
once or several times to scroll through the menu or
wait for 1 minute.
Clean the electronic filter or replace the media
filter.
See Program Setting # 6 (page 8) to change
maximum fan speed.
The sensitivity will adjust itself after some time.
Contact your distributor.
Replace the activated carbon filter or Odor Free
filter.
button on the