Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

MANUEL D'UTILISATION
USER MANUAL
RF
Mini SPY
Green
10101 B

Publicité

Chapitres

Table des Matières
loading

Sommaire des Matières pour JRI Mini SPY Green

  • Page 1 MANUEL D’UTILISATION USER MANUAL Mini SPY Green 10101 B...
  • Page 2: Table Des Matières

    Fonctionnement des leds suite à une action sur le bouton poussoir ............... 7 CARACTERISTIQUES ..........................8 VI. REMPLACEMENT DE LA PILE ......................... 8 VII. FICHE D’APTITUDE A L’EMPLOI......................9 VIII. GARANTIE ............................10 IX. CONTRAT DE MAINTENANCE ......................10 PROTECTION DE L’ENVIRONNEMENT ....................10 ©JRI Maxant...
  • Page 3: Introduction

    (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation In accordance with FCC requirements, changes or modifications not expressly approved by JRI Maxant could void the user's authority to operate this product.
  • Page 4: Sources De Perturbations

    Une paroi métallique pleine est infranchissable par les ondes. Par contre une paroi métallique ajourée laisse quand même passer les ondes en les atténuant III. PRÉSENTATION Led de fonctionnement (verte) Etiquette de Bouton poussoir personnalisation Led d’alarme (rouge) Capteur de T° ©JRI Maxant...
  • Page 5: Utilisation

    , puis clignote toutes les mesures 2’’ à une date et une heure programmée Témoin de fonctionnement (vert) : jj / mm / aa 2’’ => signale le début des mesures, puis clignote hh / mm / toutes les 2’’. ©JRI Maxant...
  • Page 6: Mode Manuel

    Un appui court sur le BP. T° OK (voyant vert) s’allume pendant 10’’. Témoin d’alarme (rouge) s’allume pendant 10’’. L’action est mémorisée et apparaîtra sur la courbe lors de l’exploitation des données dans le logiciel SIRIUS ©JRI Maxant...
  • Page 7: Fonctionnement Des Leds Suite À Une Action Sur Le Bouton Poussoir

    Démarrage Horodaté Attente démarrage des mesure les 2 leds s’allument puis Démarrage immédiat clignotent en alternance = arrêt des mesures les 2 leds s’allument puis Led Verte 10" = Top Mesure clignotent en alternance = zone arrêt des mesures ©JRI Maxant...
  • Page 8: Caracteristiques

    TENIR LA PILE A L’ECART DU FEU, NE PAS ESSAYER DE LA RECHARGER NI DE LA COURT-CIRCUITER N’UTILISER QUE DES PILES FOURNIES PAR JRI (REF : 10102) A l’issue du changement de pile redémarrer l’enregistreur en appuyant 5” sur le bouton poussoir...
  • Page 9: Fiche D'aptitude A L'emploi

    VII. FICHE D’APTITUDE À L’EMPLOI ©JRI Maxant...
  • Page 10: Garantie

    Le champs d'application de cette Directive exclut dans son article 2, les "Instruments de surveillance et de contrôle" dont font partie les produits fabriqués par la société JRI Maxant. Nos produits ne sont donc pas concernés par ces nouvelles dispositions.
  • Page 11 Leds and pushbutton actions fonctionning ....................16 REMPLACEMENT DE LA PILE / REPLACING BATTERY ................17 VI. COMPLIANCE TO THE EN 12830 ......................18 VII. WARRANTY ............................19 VIII. MAINTENANCE CONTRACT ......................... 19 IX. ENVIRONMENT PROTECTION ......................19 ©JRI Maxant...
  • Page 12: Introduction

    (2) this device must accept any interference received, including interference that may cause undesired operation In accordance with FCC requirements, changes or modifications not expressly approved by JRI Maxant could void the user's authority to operate this product.
  • Page 13: Perturbations Sources

    Obstacles thickness in the way of the waves. The absorption is more important in diagonal as  perpendicularly Waves cannot pass through full metallic walls. On the other hand, a perforated wall allows the waves passing with attenuation III. PRÉSENTATION Running led (green) Identification Alarm led (red) label Push button T° Sensor ©JRI Maxant...
  • Page 14: Use

    Working LED (green): 2’’ => starting measurements then flashes every 1 minute at a programmed date and time: Working LED (green): dd / mm / yy 2’’ => starting measurements hh / mm / ss then flashes every 2’’ ©JRI Maxant...
  • Page 15: Manual Start

    You just have to press shortly on the pushbutton. T° OK (voyant vert) s’allume pendant 10’’. Témoin d’alarme (rouge) s’allume pendant 10’’. The action is recorded and will appear on the curve when you process the data with your software Sirius. ©JRI Maxant...
  • Page 16: Leds And Pushbutton Actions Fonctionning

    = Waiting for starting measurements The 2 LEDs are on and then Immediatly flash alternatively = ending measurements The 2 LEDs are on and then Mesure Green led 10" = Top zone flash alternatively = ending measurements ©JRI Maxant...
  • Page 17: Remplacement De La Pile / Replacing Battery

    KEEP THE BATERY FAR FROM THE FIRE ; DO NOT TRY TO RELOAD OR TO SHORT CIRCUIT IT. USE ONLY BATTERIES SUPPLIED BY JRI (REF 10102) Restart the device by pressing 5’’ on the pushbutton after changing the battery...
  • Page 18: Compliance To The En 12830

    VI. COMPLIANCE TO THE EN 12830 WARrANTY ©JRI Maxant...
  • Page 19: Warranty

    Company will at its own option replace the same or refund to the Buyer the price of the product. In no circumstances will JRI Maxant' liability exceed the price of the product paid by the buyer or the cost of replacement.

Ce manuel est également adapté pour:

Mini spy rf green

Table des Matières