General
GB
The eBus CO
sensor can be connected to all CWL-180 (with extension kit )/ 300/400 Excellent, CWL-F-150
2
& /CWL-F-300 Excellent (with extension kit ) and the CWL-T-300 Excellent appliances.
A maximum of 4 CO
sensors can be connected. The CO
2
mined by the CO
sensor that requests the highest level.
2
Connection components
CWL-
180/300/400
X1
Excellent
&
1 2
CWL-T-300
Excellent
X1-2
CWL-
X1-1
1 2
F-150/300
Excellent
X15-6
X15-5
12 345 678 9
Setting CO -sensors
The CO
2
cording to the table below.
Sensor
CO
-sensor 1
ON
2
CO
-sensor 2
OFF
2
CO
-sensor 3
ON
2
CO
-sensor 4
OFF
2
Setting HRV (also refer to the installation instructions of the appliance in question)
1) Parameter 35 must be set to "ON" to activate the eBus CO
2) CO
sensor settings (refer to the table below).
2
Step no. Description
35
Switching on and off eBus CO
36
Min. PPM eBus CO
37
Max. PPM eBus CO
38
Min. PPM eBus CO
39
Max. PPM eBus CO
40
Min. PPM eBus CO
41
Max. PPM eBus CO
42
Min. PPM eBus CO
43
Max. PPM eBus CO
4
X15
green
12 345 678 9
X1/2
X1/1
X8/2
X8/1
black
green
X1/2
X1/1
X8/2
X8/1
black
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
sensor
2
sensor 1
2
sensor 1
2
-sensor 2
2
-sensor 2
2
-sensor 3
2
-sensor 3
2
-sensor 4
2
-sensor 4
2
sensors ensure optimum ventilation in the dwel-
2
2
green
X2/1
X
X
X
X
X
X X
X1
X
X
X2
X2
X2/2
X8
X7
O
O
O N
O
ON
O
ON
ON
ON
ON
O
N
N
N N
N
N
N
N
N
N
X7/1
1 2 3 4 5
1 2 3 4 5
X7/2
black
CO
-sensor 1
2
green
X2/1
X1
X1
X1
X
X1
1
1
1
1
1
1
1
X
X
X
X 2
X
X
X
X
X2
X
X
X 2
X
X
X
X2/2
X8
X7
O
O
O
O
ON
O N
O N
ON
O
O
O
O
ON
ON
O
ON
O
O
O N
O
N
N
N
X7/1
1
1
1
1
1
1
1
1 2 3 4 5
1
1
2 3 4
X7/2
black
CO
-sensor 1
2
sensor has a unique combination and must be set ac-
2
OFF
ON
OFF
1 2 3 4 5
OFF
OFF
sensors.
2
Factory setting
Setting range Step
OFF
ON - OFF
400
1200
400
1200
400-2000
400
1200
400
1200
CO - sensor
-
green
X1/1
X2
X2
X
X
X
X
X
X
X
X1
X
X1/2
X8
X7
O N
ON
O
O
ON
ON
O
ON
ON
N
N
N
N
N
N N
N
N
N
N
X8/1
1 2 3 4 5
1 2 3 4 5
X8/2
black
CO
-sensor 2
2
green
X1/1
X2
X2
X
X
X
X1
X
X
X
X
X1/2
X8
X7
O
ON
ON
ON
O
O
N
N
N
N
N
N
N
N
N
N N N
N
N
N
N
N
N
N
N
X8/1
1 2 3 4 5
1 2 3 4 5
X8/2
black
CO
-sensor 2
2
ON
1 2 3 4 5
Display text + symbols
-
CO2 EB
PPM MIN
PPM MAX
PPM MIN
PPM MAX
25
PPM MIN
PPM MAX
PPM MIN
PPM MAX
Art.-Nr.: 30 64 363
green
black
green
black

Publicité

loading

Ce manuel est également adapté pour:

30 64 363