Dometic GROUP WAECO PerfectCharge MCA1215 Instructions De Montage Et De Service page 51

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 65
MCA1215 – MCA2440
8.2
Charge versions
fig. 3, page 5
Battery sensor
MCA-HS1 (IBS)
– without; ✓ with
Charging the battery
➤ Connect the battery to the "DC OUTPUT" socket of the MCA battery
charger.
 Make sure the polarity of the connections is correct.
Charging the starter battery (MCA1215, 1225, 1235 only)
➤ Connect the starter battery to the "ESB" socket of the MCA battery
charger.
 Make sure the polarity of the connections is correct.
Charging using the temperature sensor MCA-TS1 (accessory)
➤ Connect the temperature sensor to the TEMP/LIN connection.
✓The charging voltage is adjusted according to the temperature measured.
Charging using the IBS battery sensor MCA-HS1 (accessory)
➤ Connect the battery sensor to the TEMP/LIN connection.
✓The battery sensor transmits the battery temperature and the battery
voltage to the charger via the LIN communication port. The charging
voltage is regulated according to the temperature. Any potential loss of
voltage in the connecting cables is also compensated.
EN
Perfect Control
MPC01
Connecting the device
fig. 4, page 5
Remote control
Temperature sensor
MCA-RC1
MCA-TS1 or
Battery sensor
MCA-HS1 (IBS)
51

Publicité

Table des Matières
loading

Table des Matières