JBu-100-e
JBu-100-eP
JBu-100-l-e
JBu-100-l-eP
english
PTB 09 ATEX 1061 U
IECEx PTB 09.0039U
Rated voltage:
Ambient temperature: JBU-100-E(P): -50°C to +56°C**
**: Special conditions for safe use may apply.
Ex em ll T *
* For system Temperature Code, see heating cable or design documentation
Rated voltage:
Ambient temperature: -40°C to +40°C
BR-Ex e II
BR-Ex em II
For proper installation, follow carefully the installation instructions of the applicable
connection kits: C25-100, C25-21, C25-100-METAL or CCON25-100
Maximum pipe temperature:
Heater type
BTV
QTVR
XTV
KTV
VPL
VPL: Maximum pipe temperature in dependence of heater type and voltage
Heater Type
Cable
5VPL2-CT
10VPL2-CT
15VPL2-CT
20VPL2-CT
Heater Type
Cable
5VPL4-CT
10VPL4-CT
15VPL4-CT
20VPL4-CT
Special conditions for safe use using ATEX or IECEx approvals:
For ambient temperatures >+40°C:
Use a power cable with continuous temperature resistance of minimum +90°C.
Use a metallic power cable gland approved for use in hazardous areas
(for example GL-38-M25-METAL) and heating cable gland (C25-100-METAL).
For voltages >254Vac and BTV, QTVR, XTV or KTV heating cables:
Use a power cable with continuous temperature resistance of minimum +90°C.
Use a metallic power cable gland approved for use in hazardous areas
(for example GL-38-M25-METAL) and heating cable gland (C25-100-METAL).
II 2G Ex e (e mb) II
II 2D Ex tD (tD mbD) A21 IP66
Ex e (e mb) II
Ex tD (tD mbD) A21 IP66
JBU-100-E(P): 480 Vac**
JBU-100-L-E(P): 254 Vac
JBU-100-L-E(P): -40°C to +40°C
277 Vac
T
continuous
max
65°C
110°C
120°C
150°C
See tables below
208 Vac
230 Vac
235°C
230°C
220°C
210°C
200°C
180°C
150°C
150°C
385 Vac
230°C
215°C
195°C
150°C
T
intermittent
max
1000h cumulative
85°C
110°C
215°C
215°C
T
pipe
max
254 Vac
277 Vac
225°C
225°C
200°C
195°C
145°C
105°C
Not allowed
T
pipe
max
400 Vac
480 Vac
230°C
230°C
215°C
205°C
195°C
160°C
150°C
150°C
T
power off
max
260°C