Télécharger Imprimer la page

Würth AccuLuber 14.4-S Mode D'emploi page 9

Publicité

Les langues disponibles

Les langues disponibles

Safety Instructions :
Non-compliance with the safety instructions can result in danger both to persons and to the
environment and the
to the loss of any claims for damages. The operator
the contents of the Operating Instructions, particularly the Safety Instructions are known to
the operating personal.
The unit must not be operated in potentially explosive areas.
-
Protect the unit from damage and the effects of heat.
-
The unit must only be operated with the 14.4V battery originally intended for it.
-
The use of a different battery could lead to damage to the unit, or to a risk of fire.
The battery must only be charged with the charger provided for the purpose.
-
-
Before charging ensure that the mains voltage complies with the details on the rating plate of the
charger.
The ventilation slots on the top and bottom of the charger must not be covered during the charging
-
process.
Do not charge the battery when the temperature is under 0°C or over 40°C.
-
-
Do not charge the battery in damp or wet surroundings.
-
Only dispose of used batteries properly in accordance with EC Guideline 91/157/EWG.
The battery contains rechargeable NiCd cells.
The setting of the of the pressure relief valve must never be changed.
-
In case of blocking do not continue pressing the START switch. There is a danger of the motor
-
overheating and being damaged.
Never point the lubrication hose at people or animals! Risk of injury!!
-
Before repair or maintenance work the current supply must be shut off. The battery must be taken
out of the handle.
-
Leather industrial gloves and also safety glasses must be worn when using the unit.
When lubricating, only hold the high pressure hose in the area of the nozzle.
-
Do not bend the high pressure hose sharply.
-
Make a regular check on the pressurised components (high pressure hose) and also on the live
-
parts (charger) for possible damage. Defective parts must be replaced with genuine spares
without delay.
The use of accessory components e.g. hoses and connection fittings, which are not supplied by
-
MATO, can in some cases give rise to the risk of accidents. No liability can be accepted for
accidents or damage caused by components from other sources.
Modifications or changes to the equipment are only allowed after discussion with the maker.
-
The safe operation of the equipment is only guaranteed if used in accordance with the directions.
-
Maintenance, inspection and repairs must only be carried out by qualified specialist personnel,
-
who have acquainted themselves with the subject by studying the operating instructions.
Notes on malfunctions:
Symptom
The motor will not run.
Pressure relief valve
opens when grease is
being delivered.
Unit not pumping grease.
The unit continually
breaks of delivery of
grease.
The battery is not taking
a charge
equipment. Non-compliance with the safety instructions can lead
Possible cause
The battery is flat or defective.
The wiring to the motor ist defective.
Lubricating nipple defective or
blocked.
Lubricating pipe defective or blocked.
Bearing point defective or blocked.
The grease gun container is empty.
The grease feed is interrupted.
Due to filling with loose grease there is
air trapped in the grease.
No mains voltage to charger.
Battery defective or worn out.
of the equipment must ensure that
Cure
Charge or replace the battery .
Remove the battery, disassemble the
handle and check for loose connections.
Check affected parts and if necessary
clean or replace. .
Check the level in the grease container.
Bleed out the air.
Empty the grease gun container and bleed
the air out of the refilled gun.
Check whether the socket is live.
Replace the battery