Once the receiver is installed in the hanger bracket, make the electrical connections below (see diagram
below) :
1/ CONNECTIONS FROM CEILING FAN TO RECEIVER
- Connect the connector of the ceiling fan (3 wires : pink / grey / red) to the receiver.
2/ CONNECTIONS FROM RECEIVER TO HANGER BRACKET
- Connect the connector of the hanger bracket (3 wires : brown or black / blue / yellow and green) to the re-
ceiver.
The brown or black wire corresponds to the phase (Line), the blue wire corresponds to the neutral, the yellow
and green wire corresponds to the ground (Earth).
3/ CONNECTIONS FROM HANGER BRACKET TO AC CEILING POWER
By using the connecting terminals provided on the hanger bracket :
- Connect the phase of the ceiling to the phase of the hanger bracket in the domino L (LINE : black or brown
wire of the hanger bracket).
- Connect the neutral of the ceiling with the neutral of the hanger bracket in the domino N (NEUTRAL : blue
wire of the hanger bracket).
4/ GROUNDING
- Connect the ground wire of the ceiling to the ground wire of the hanger bracket in the domino E (EARTH :
yellow and green wire of the hanger bracket).
- Connect one of the two grounding connectors of the hanger bracket to the one of the hanger ball.
- Connect the other grounding connector of the hanger bracket to the one of the ceiling fan.
27